MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1039/d4ra07986h

Медицинская библиотека · RSC advances · 2025

Microstructure, wear, and corrosion properties of PEEK-based composite coating incorporating titania- and copper-doped mesoporous bioactive glass nanoparticles.

Ahmad Khalil, Imran Ayman, Minhas Badar, Aizaz Aqsa, Khaliq Abdul, Wadood Abdul, Haseeb Nawaz Muhammad, Chughtai Muhammad Tajammal, Batul Rahila, Ur Rehman Muhammad Atiq

СтатьяПеревод в очереди

Аннотация

Poor wear- and corrosion-resistance of 316L SS implants are critical problems in orthopedic implants. This study aims to improve the wear- and corrosion-resistance of 316L SS through surface coating. In this study, a bilayer composite coating consisting of polyether ether ketone (PEEK) as the first layer, and titania (TiO2)- and Cu-doped mesoporous bioactive glass nanoparticles (Cu-MBGNs) were deposited as the second layer on a 316L SS via electrophoretic deposition (EPD). Scanning electron microscopy (SEM) images of the bilayer composite coating showed the distribution of TiO2 and Cu-MBGNs within the PEEK matrix. Energy dispersive spectroscopy (EDS) analysis confirmed the presence of TiO2 and Cu-MBGNs in the bilayer composite coating. Fourier transform infrared spectroscopy (FTIR) identified the functional groups attributed to the PEEK, TiO2 and Cu-MBGNs. X-ray diffraction (XRD) analysis confirmed the presence of TiO2 (anatase) and Cu-MBGNs in the bilayer composite coating. The coating exhibited a strong antibacterial effect against Staphylococcus aureus (S. aureus) and Escherichia coli (E. coli). Incorporating TiO2/Cu-MBGNs into the bilayer composite coating significantly modified the surface of 316L SS by improving the wear- and corrosion-resistance. Pin on disc test revealed that the specific wear rate of ∼(0.4570 ± 0.009) × 10-6 mm3 Nm-1 of the PEEK coating decreased to (0.0482 ± 0.007) × 10-6 mm3 Nm-1 on incorporating TiO2/Cu-MBGNs in PEEK coating under a normal load of 10 N in Dulbecco's Modified Eagle Medium (DMEM). Furthermore, electrochemical impedance spectroscopy (EIS) results revealed that the impedance value of the bilayer composite coating remained ∼4.56 × 105 Ω cm2 compared to 8.81 × 103 Ω cm2 of 316L SS after 24 h immersion in phosphate-buffered saline (PBS). Thus, this study demonstrated that the wear- and corrosion-resistance of 316L SS can be improved by incorporating TiO2/Cu-MBGNs in PEEK-based composite coatings for orthopedic applications.

Для цитирования: Ahmad Khalil, Imran Ayman, Minhas Badar, Aizaz Aqsa, Khaliq Abdul, Wadood Abdul, Haseeb Nawaz Muhammad, Chughtai Muhammad Tajammal, Batul Rahila, Ur Rehman Muhammad Atiq. Microstructure, wear, and corrosion properties of PEEK-based composite coating incorporating titania- and copper-doped mesoporous bioactive glass nanoparticles.. RSC advances. 2025. DOI: 10.1039/d4ra07986h.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.