MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-021-81365-7

Медицинская библиотека · Scientific reports · 2021

Analysis of SteraMist ionized hydrogen peroxide technology in the sterilization of N95 respirators and other PPE.

Cramer Avilash K, Plana Deborah, Yang Helen, Carmack Mary M, Tian Enze, Sinha Michael S, Krikorian David, Turner David, Mo Jinhan, Li Ju, Gupta Rajiv, Manning Heather, Bourgeois Florence T, Yu Sherry H, Sorger Peter K, LeBoeuf Nicole R

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

The COVID-19 pandemic has led to widespread shortages of personal protective equipment (PPE) for healthcare workers, including of N95 masks (filtering facepiece respirators; FFRs). These masks are intended for single use but their sterilization and subsequent reuse has the potential to substantially mitigate shortages. Here we investigate PPE sterilization using ionized hydrogen peroxide (iHP), generated by SteraMist equipment (TOMI; Frederick, MD), in a sealed environment chamber. The efficacy of sterilization by iHP was assessed using bacterial spores in biological indicator assemblies. After one or more iHP treatments, five models of N95 masks from three manufacturers were assessed for retention of function based on their ability to form an airtight seal (measured using a quantitative fit test) and filter aerosolized particles. Filtration testing was performed at a university lab and at a National Institute for Occupational Safety and Health (NIOSH) pre-certification laboratory. The data demonstrate that N95 masks sterilized using SteraMist iHP technology retain filtration efficiency up to ten cycles, the maximum number tested to date. A typical iHP environment chamber with a volume of ~ 80 m3 can treat ~ 7000 masks and other items (e.g. other PPE, iPADs), making this an effective approach for a busy medical center.

Для цитирования: Cramer Avilash K, Plana Deborah, Yang Helen, Carmack Mary M, Tian Enze, Sinha Michael S, Krikorian David, Turner David, Mo Jinhan, Li Ju, Gupta Rajiv, Manning Heather, Bourgeois Florence T, Yu Sherry H, Sorger Peter K, LeBoeuf Nicole R. Analysis of SteraMist ionized hydrogen peroxide technology in the sterilization of N95 respirators and other PPE.. Scientific reports. 2021. DOI: 10.1038/s41598-021-81365-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.