Anthony Mary S, Reed Susan D, Armstrong Mary Anne, Getahun Darios, Gatz Jennifer L, Saltus Catherine W, Zhou Xiaolei, Schoendorf Juliane, Postlethwaite Debbie A, Raine-Bennett Tina, Fassett Michael J, Peipert Jeffrey F, Ritchey Mary E, Ichikawa Laura E, Lynen Richard, Alabaster Amy L, Merchant Maqdooda, Chiu Vicki Y, Shi Jiaxiao M, Xie Fagen, Hui Siu L, Wang Jinyi, Hunter Shannon, Bartsch Jennifer, Frenz Ann-Kathrin, Chillemi Giulia, Im Theresa M, Takhar Harpreet S, Asiimwe Alex
Аннотация
OBJECTIVE: We aimed to describe the APEX-IUD study design, methodology, and analytical plan and present population characteristics, size of risk factor groups, and duration of follow-up.
STUDY DESIGN: APEX-IUD study was a retrospective cohort study conducted in 4 organizations with access to electronic health records: Kaiser Permanente Northern California, Kaiser Permanente Southern California, Kaiser Permanente Washington, and Regenstrief Institute in Indiana. Variables were identified through structured data (eg, diagnostic, procedural, medication codes) and unstructured data (eg, clinical notes) via natural language processing. Outcomes include uterine perforation and device expulsion; potential risk factors were breastfeeding at insertion, postpartum timing of insertion, device type, and menorrhagia diagnosis in the year before insertion. Covariates include demographic characteristics, clinical characteristics, and procedure-related variables, such as difficult insertion. The first potential date of inclusion for eligible women varies by research site (from January 1, 2001 to January 1, 2010). Follow-up begins at insertion and ends at first occurrence of an outcome of interest, a censoring event (device removal or reinsertion, pregnancy, hysterectomy, sterilization, device expiration, death, disenrollment, last clinical encounter), or end of the study period (June 30, 2018). Comparisons of levels of exposure variables were made using Cox regression models with confounding adjusted by propensity score weighting using overlap weights.
RESULTS: The study population includes 326,658 women with at least 1 device insertion during the study period (Kaiser Permanente Northern California, 161,442; Kaiser Permanente Southern California, 123,214; Kaiser Permanente Washington, 20,526; Regenstrief Institute, 21,476). The median duration of continuous enrollment was 90 (site medians 74-177) months. The mean age was 32 years, and the population was racially and ethnically diverse across the 4 sites. The mean body mass index was 28.5 kg/m2, and of the women included in the study, 10.0% had menorrhagia ≤12 months before insertion, 5.3% had uterine fibroids, and 10% were recent smokers; furthermore, among these women, 79.4% had levonorgestrel-releasing devices, and 19.5% had copper devices. Across sites, 97,824 women had an intrauterine device insertion at ≤52 weeks after delivery, of which 94,817 women (97%) had breastfeeding status at insertion determined; in addition, 228,834 women had intrauterine device insertion at >52 weeks after delivery or no evidence of a delivery in their health record.
CONCLUSION: Combining retrospective data from multiple sites allowed for a large and diverse study population. Collaboration with clinicians in the study design and validation of outcomes ensured that the APEX-IUD study results reflect current United States clinical practice. Results from this study will provide valuable information based on real-world evidence about risk factors for intrauterine devices perforation and expulsion for clinicians.