MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/pxr.0000000000000392

Медицинская библиотека · Prosthetics and orthotics international · 2024

Virtual reality-based myoelectric prosthetic control training: Effects of action observation and motor imagery with visual feedback of electromyographic signals.

Yoshimura Manabu, Kurumadani Hiroshi, Ito Tomotaka, Hosokawa Takayuki, Hirata Junya, Senoo Katsutoshi, Kinoshita Seiji, Date Shota, Hanayama Kozo, Sunagawa Toru

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Conventional myoelectric prostheses (myo-prostheses) training involves repetitive grasping and manipulation training, which requires considerable training time. It is necessary to develop a short and efficient myo-prostheses training. This study aimed to verify the immediate and sustained effects of action observation and motor imagery (AOMI) using virtual reality (VR) on myo-prostheses control and clarify the effect of visual feedback of electromyogram (EMG) signals during AOMI using VR.

STUDY DESIGN AND

METHODS

We evaluated 24 healthy right-handed individuals wearing a myo-prostheses simulator in their dominant hands. We divided participants into 3 groups: VR video observation with EMG presentation during manipulation (VR+), VR video observation without EMG presentation (VR), and control group. We evaluated prosthetic control skills using the Grasp Force Adjustment Test (GFAT) and Bowknot task immediately before and after AOMI and 1 week later. In addition, we evaluated the level of immersion during AOMI.

RESULTS

The rate of change in the GFAT 1 week after the intervention was significantly greater in the VR+ ( P < 0.05, d = 1.32) and VR ( P < 0.01, d = 2.34) groups than in the control group. Immersion was significantly higher in the VR+ and VR groups than in the control group. The condition and time required for GFAT had significant effects, although the post-hoc test showed no significant difference between VR+ and VR groups.

CONCLUSIONS

AOMI using VR had sustained effects on motor learning of myo-prosthetic control despite EMG presentation. Therefore, AOMI, using VR, manipulates prostheses once learned, and it might be used for future training of myo-prosthetic control.

Для цитирования: Yoshimura Manabu, Kurumadani Hiroshi, Ito Tomotaka, Hosokawa Takayuki, Hirata Junya, Senoo Katsutoshi, Kinoshita Seiji, Date Shota, Hanayama Kozo, Sunagawa Toru. Virtual reality-based myoelectric prosthetic control training: Effects of action observation and motor imagery with visual feedback of electromyographic signals.. Prosthetics and orthotics international. 2024. DOI: 10.1097/pxr.0000000000000392.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.