PURPOSE: To evaluate the influence of resin cement type, surface pretreatment and autoclave sterilization on the retention of Y-TZP crowns to Ti-base abutments.

METHODS

Y-TZP crowns were designed and milled to fit Ti-base abutments. Crowns were cemented using either a conventional resin cement (conventional) with a universal adhesive or a self-adhesive resin cement (self-adhesive), both following no surface pretreatment (No) or Ti-base abutment sandblasting (SB) (n=20/group). Half of the cemented samples were subjected to in-office autoclave sterilization. Pullout testing was performed in a universal testing machine at a speed of 1 mm/min until crown displacement. Data were statistically evaluated through a linear mixed model following post hoc comparisons by LSD test.

RESULTS

Pullout data as a function of cement type demonstrated higher retention for conventional relative to self-adhesive cement (p < 0.001). Ti-base sandblasting (SB) favored crown retentiveness over No pretreatment (p < 0.001). Sterilized crowns exhibited higher pullout values than non-sterile (p=0.036). All the two- and three-factor interaction analyses corroborated with the superior adhesive strength of conventional compared to self-adhesive cement (all, p < 0.011), as well as, SB relative to No pretreatment (all, p < 0.024). While autoclave sterilization maximized bond strength when self-adhesive cement (data collapsed over surface pretreatment, p < 0.050) and No pretreatment were evaluated (data collapsed over surface pretreatment, p < 0.013), no significant difference was observed for conventional resin cement (p=0.280) and SB (p=0.878) groups.

CONCLUSIONS

Conventional resin cement and/or Ti-base sandblasting increased Y-TZP crown retentiveness, with no significant influence of autoclave sterilization. Autoclaving increased retentiveness when self-adhesive cement and/or no Ti-base pretreatment were used.

Для цитирования: T P Bergamo Edmara, Zahoui Abbas, Luri Amorin Ikejiri Larissa, Marun Manoela, Peixoto da Silva Kimberly, G Coelho Paulo, Soares Simone, A Bonfante Estevam. Retention of zirconia crowns to Ti-base abutments: effect of luting protocol, abutment treatment and autoclave sterilization.. Journal of prosthodontic research. 2020. DOI: 10.2186/jpr.jpor_2019_537.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.