MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajic.2019.08.018

Медицинская библиотека · American journal of infection control · 2019

Assessment of surgical instrument bioburden after steam sterilization: A pilot study.

Resendiz Marisol, Horseman Timothy S, Hover Andrew J, Bradley David F, Lustik Michael B, West Gordon F

СтатьяПеревод в очереди

Аннотация

In environments in which manual decontamination and steam sterilization remains the primary method of sterilization, biofilm formation can increase the risk of disease transmission. To determine the risk of bacterial survival and contamination on surgical instruments, inoculated blood was dried on one instrument and steam sterilized (wrapped or unwrapped) in a set of 4 (including 3 clean). Two of 3 pathogens were recovered at a rate of 15% for unwrapped sets and 33% for wrapped sets.

Для цитирования: Resendiz Marisol, Horseman Timothy S, Hover Andrew J, Bradley David F, Lustik Michael B, West Gordon F. Assessment of surgical instrument bioburden after steam sterilization: A pilot study.. American journal of infection control. 2019. DOI: 10.1016/j.ajic.2019.08.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.