Effect of cleaning guidelines implementation on microbial colony count of laparoscopic instruments: A study in a public hospital in Iran.
Аннотация
INTRODUCTION
Some countries have implemented reuse of laparoscopic instruments for cost-effective purposes. An accurate cleaning as the first step of reprocessing would lead to the effective sterilization. The purpose was to evaluate the effect of cleaning guidelines implementation on microbial load of laparoscopic instruments which were used in laparoscopic cholecystectomy surgery.
METHODS
This experimental study was done in an educational hospital, in 2017 and included a total of 128 laparoscopic instruments randomly selected from cholecystectomy surgeries and divided into two cleaning groups. The instruments were checked out in terms of number (colony-forming units [CFU]/mL) and type of microorganisms in two groups of routine cleaning and according to guideline cleaning. This guideline was indigenous and taken from successful instruction in this context that was presented by the Association for the Advancement of Medical Instrumentation (AAMI). The appropriate statistical analysis was conducted by SPSS version 19.
RESULTS
The average microbial load was 2.4 × 106 CFU/100 mL after clinical use. It was reduced to 7.2 × 105 CFU/100 mL in the control group and 3.4 × 104 CFU/100 mL in the intervention group, after the cleaning process. The most common microorganisms that were isolated immediately after clinical use were Escherichia coli 81.2%, Pseudomonas 68.8%, Klebsiella 57.8%, and spp., and so on.
CONCLUSION
The AAMI cleaning method is recommended to be utilized by operating room nurses for laparoscopic instruments.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.