Wang Shan-Ni, Li Jing-Jing, Liu Ying-Xin, Lin Zhi, Qiao Jiao-Jiao, Chen Li-Hua, Li Yu, Wu Yong, Wang Mei-Mei, Liu Yun-Bo, Yan Chen, Chen Zhi-Heng, Gao Chang-Qing
Аннотация
BACKGROUND AND OBJECTIVES: Non-thermal atmospheric plasma treatment and pulsed xenon ultraviolet (PX-UV) treatment are widely used in disinfection of hospital environments. However, their effectiveness has not been evaluated against a comparator. The objective of this study is to evaluate their effectiveness in the disinfection of pathogens in the air in hospital blood sampling rooms.
METHODS: Samples were taken from the air before and after disinfection with PX-UV and non-thermal atmospheric plasma. We counted bacterial colonies and identified the types of bacteria.
RESULTS: Non-thermal plasma treatment significantly reduced bacterial counts in the air, the median reduced from 1 before treatment to zero afterwards (p = 0.03). PX-UV treatment also significantly reduced bacterial counts in the air (p = 0.01), the median reduced from 1.5 before treatment to zero afterwards. Pathogens identified in the current study include nosocomial bacteria, such as Staphylococcus aureus, Staphylococcus epidermidis, and yeast.
CONCLUSION: Disinfection of blood sampling sites is essential in a health service department. The efficiency of PX-UV and non-thermal atmospheric plasma treatment are comparable in air disinfection.
METHODS: Samples were taken from the air before and after disinfection with PX-UV and non-thermal atmospheric plasma. We counted bacterial colonies and identified the types of bacteria.
RESULTS: Non-thermal plasma treatment significantly reduced bacterial counts in the air, the median reduced from 1 before treatment to zero afterwards (p = 0.03). PX-UV treatment also significantly reduced bacterial counts in the air (p = 0.01), the median reduced from 1.5 before treatment to zero afterwards. Pathogens identified in the current study include nosocomial bacteria, such as Staphylococcus aureus, Staphylococcus epidermidis, and yeast.
CONCLUSION: Disinfection of blood sampling sites is essential in a health service department. The efficiency of PX-UV and non-thermal atmospheric plasma treatment are comparable in air disinfection.