MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/09205063.2024.2365047

Медицинская библиотека · Journal of biomaterials science. Polymer edition · 2024

Fabrication of PTFE + TiO2/Ag coatings on 316L/polydopamine with advanced mechanical, bio-corrosion, and antibacterial properties for stainless steel Catheters.

Sheikhzadeh Mohammad Sajjad, Ahmadi Reza, Ghamari Niloufar, Afshar Abdollah

СтатьяПеревод в очереди

Аннотация

This study explores the corrosion resistance and antibacterial properties of a PTFE + TiO2/Ag coating applied to 316 L stainless steel. To enhance adhesion, a polydopamine interlayer was chemically deposited onto the steel surface. The PTFE + TiO2 coating was subsequently applied through immersion, followed by the deposition of silver nanoparticles using a chemical method. Optimization of the polydopamine interlayer involved varying temperature, time, stirring speed, and drying parameters. The optimal conditions for the polydopamine interlayer were determined to be 60 °C for 1 h, 300 rpm stirring, and 24-h drying in a freeze dryer. Analytical results demonstrated that both the PTFE + TiO2 and PTFE/PTFE + TiO2/Ag coatings exhibited exceptional corrosion resistance, with corrosion currents of 3.3 × 10-5 and 3.2 × 10-4 μA/cm2, respectively. Antibacterial assessments showcased the remarkable ability of the PTFE/PTFE + TiO2/Ag coating, containing 5% silver content, to effectively inhibit bacterial penetration within a 6.5 mm radius. Furthermore, this coating displayed a water contact angle of 143°, classifying it as a hydrophobic coating. The photocatalytic efficiency (Rs) was determined to be 3.18 × 10-3 A/W, a performance level comparable to that of a standard UV sensor. These findings underscore the substantial enhancements in corrosion resistance, antibacterial performance, and hydrophobic characteristics achieved with the PTFE + TiO2/Ag coating, particularly through the novel optimization of the polydopamine interlayer. This coating exhibits great promise for multifunctional protective applications in diverse fields, particularly demonstrating its suitability for implants and bio-coatings.

Для цитирования: Sheikhzadeh Mohammad Sajjad, Ahmadi Reza, Ghamari Niloufar, Afshar Abdollah. Fabrication of PTFE + TiO2/Ag coatings on 316L/polydopamine with advanced mechanical, bio-corrosion, and antibacterial properties for stainless steel Catheters.. Journal of biomaterials science. Polymer edition. 2024. DOI: 10.1080/09205063.2024.2365047.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.