Reproducibility, Accuracy and Effect of Autoclave Sterilization on a Thermoplastic Three-Dimensional Model Printed by a Desktop Fused Deposition Modelling Three-Dimensional Printer.

Boursier Jean-François, Fournet Alexandre, Bassanino Jean, Manassero Mathieu, Bedu Anne-Sophie, Leperlier Dimitri

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

The main purpose of this study was to determine the reproducibility and accuracy of a three-dimensional (3D) bone model printed on a desktop 3D-printer based on fused deposition modelling (FDM) technology with polylactic acid (PLA) and the effect of autoclave sterilization on the printed models.

METHODS

Computed tomographic images of the tibia were obtained from 10 feline cadavers, used to create a bone surface-rendering file and sent to the 3D printing software. Right and left tibias were each printed five times with the FDM desktop 3D printer using PLA plastic material. Plastic models and cadaveric bones were measured with a profile projector device at six predetermined landmarks. Plastic bones were then sterilized using an autoclave before being re-measured applying the same method. Analyses of printed model size reliability were conducted using intra-class correlation coefficients (ICC) and Bland-Altman plots.

RESULTS

The ICC always showed an almost perfect agreement when comparing 3D-printed models issued from the same cadaveric bone. The ICC showed moderate agreement for one measurement and strong/perfect agreement for others when comparing a cadaveric bone with the corresponding 3D model. Concerning the comparison of the same 3D-printed model, before and after sterilization, ICC showed either strong or perfect agreement.

CLINICAL SIGNIFICANCE: Rapid-prototyping with our FDM desktop 3D-printer using PLA was an accurate, a reproducible and a sterilization-compliant way to obtain 3D plastic models.

Для цитирования: Boursier Jean-François, Fournet Alexandre, Bassanino Jean, Manassero Mathieu, Bedu Anne-Sophie, Leperlier Dimitri. Reproducibility, Accuracy and Effect of Autoclave Sterilization on a Thermoplastic Three-Dimensional Model Printed by a Desktop Fused Deposition Modelling Three-Dimensional Printer.. Veterinary and comparative orthopaedics and traumatology : V.C.O.T. 2018. DOI: 10.1055/s-0038-1668113.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.