BACKGROUND

Patients go without pacemaker, defibrillator, and cardiac resynchronization therapies (devices) each year due to the prohibitive costs of devices.

OBJECTIVE

We sought to examine data available from studies regarding contemporary risks of reused devices in comparison with new devices.

METHODS

We searched online indexing sites to identify recent studies. Peer-reviewed manuscripts reporting infection, malfunction, premature battery depletion, and device-related death with reused devices were included. The primary study outcome was the composite risk of infection, malfunction, premature battery depletion, and death. Secondary outcomes were the individual risks.

RESULTS

Nine observational studies (published 2009-2017) were identified totaling 2,302 devices (2,017 pacemakers, 285 defibrillators). Five controlled trials were included in meta-analysis (2,114 devices; 1,258 new vs 856 reused). All device reuse protocols employed interrogation to confirm longevity and functionality, disinfectant therapy, and, usually, additional biocidal agents, packaging, and ethylene oxide gas sterilization. Demographic characteristics, indications for pacing, and median follow-up were similar. There were no device-related deaths reported and no statistically significant difference in risk between new versus reused devices for the primary outcome (2.23% vs 3.86% respectively, P = 0.807, odds ratio = 0.76). There were no significant differences seen in the secondary outcomes for the individual risks of infection, malfunction, and premature battery depletion.

CONCLUSIONS

Device reuse utilizing modern protocols did not significantly increase risk of infection, malfunction, premature battery depletion, or device-related death in observational studies. These data provide rationale for proceeding with a prospective multicenter noninferiority randomized control trial.

Для цитирования: Sinha Sunil K, Sivasambu Bhradeev, Yenokyan Gayane, Crawford Thomas C, Chrispin Jonathan, Eagle Kim A, Barth Andreas S, Rickard John Jack, Spragg David D, Vlay Stephen C, Berger Ronald, Love Charles, Calkins Hugh, Tomaselli Gordon F, Marine Joseph E. Worldwide pacemaker and defibrillator reuse: Systematic review and meta-analysis of contemporary trials.. Pacing and clinical electrophysiology : PACE. 2018. DOI: 10.1111/pace.13488.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.