Hysteroscopic tubal occlusion using iso-amyl-2-cyanoacrylate in patients with hydrosalpinx.
Аннотация
AIM: The aim of this work is to assess the effectiveness of hysteroscopic tubal occlusion using iso-amyl-2-cyanoacrylate, among infertile women with hydrosalpinx prior to in vitro fertilization (IVF).
METHODS
Hysteroscopic injection of fallopian tubes with hydrosalpinx by 0.5 mL iso-amyl-2-cyanoacrylate was done in 40 infertile women planning for IVF. The patients were then followed-up after 1 and 3 months, with hysterosalpingography (HSG) to confirm complete tubal occlusion. Reinjection with iso-amyl-2-cyanoacrylate was done in these patients with incomplete tubal occlusion after 1 month of the first injection, followed by HSG 2 months later to confirm complete tubal occlusion. Data were prescribed as range, mean and standard deviation (for parametric variables) and range, number and percentage (for categorical variables).
RESULTS
The total number of tubes injected in this study was 54, 42 (77.8%) of which were completely occluded after one injection while 12 (22.2%) were partially occluded. Reinjection of the partially occluded tubes was done, and (HSG) of all patients after 3 months of the primary injection confirmed 48 (88.9%) of the tubes completely occluded while 6 (11.1%) remained partially occluded. Thirty-two (80%) patients underwent one cycle of IVF/ET (embryo transfer), while 8 (20%) patients did not appear for follow-up. Among the patients who underwent IVF/ET, 24 (75%) got pregnant, while 8 (25%) failed to conceive. Among the pregnant patients, 8 (33.3%) delivered at term, 3 (12.5%) had first trimester abortion, while the remaining 13 (54.2%) did not deliver yet.
CONCLUSION
Iso-amyl-2-cyanoacrylate used for hysteroscopic tubal occlusion in patients with hydrosalpinx prior to IVF is safe and effective.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.