A prospective analysis of clinical detection of defective wrapping by operating room staff.

Mobley Kyle S, Jackson J Benjamin

СтатьяПеревод в очереди

Аннотация

Surgical instrument trays are wrapped for sterilization, and these wraps are inspected by operating room personnel for defects before using the instruments. In this study, we intentionally damaged wraps, and these wraps were evaluated by operating room personnel. Examiners correctly identified a wrapper's sterile integrity with an overall 56.1% accuracy, with correct identification of 67.2% for defects between 2 and 5 cm. However, studies have shown bacterial contamination through defects as small as 1.1 mm. This study suggests that the current method for assessing sterility is inadequate.