MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jor.23764

Медицинская библиотека · Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2017

Flash autoclave settings may influence eradication but not presence of well-established biofilms on orthopaedic implant material.

Williams Dustin L, Taylor Nicholas B, Epperson Richard T, Rothberg David L

СтатьяПоддержка правительства СШАПеревод в очереди

Аннотация

Flash autoclaving is one of the most frequently utilized methods of sterilizing devices, implants or other materials. For a number of decades, it has been common practice for surgeons to remove implantable devices, flash autoclave and then reimplant them in a patient. Data have not yet indicated the potential for biofilms to survive or remain on the surface of orthopaedic-relevant materials following flash autoclave. In this study, monomicrobial and polymicrobial biofilms were grown on the surface of clinically relevant titanium materials and exposed to flash autoclave settings that included varying times and temperatures. Data indicated that when the sterilization and control temperatures of an autoclave were the same, biofilms were able to survive flash autoclaving that was performed for a short duration. Higher temperature and increased duration rendered biofilms non-viable, but none of the autoclave settings had the ability to remove or disperse the presence of biofilms from the titanium surfaces. These findings may be beneficial for facilities, clinics, or hospitals to consider if biofilms are suspected to be present on materials or devices, in particular implants that have had associated infection and are considered for re-implantation. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1543-1550, 2018.

Для цитирования: Williams Dustin L, Taylor Nicholas B, Epperson Richard T, Rothberg David L. Flash autoclave settings may influence eradication but not presence of well-established biofilms on orthopaedic implant material.. Journal of orthopaedic research : official publication of the Orthopaedic Research Society. 2017. DOI: 10.1002/jor.23764.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.