MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.contraception.2017.06.013

Медицинская библиотека · Contraception · 2017

Pressure dynamics in the non-gravid uterus: intrauterine pressure cannot confirm tubal occlusion after non-surgical permanent contraception.

Patil Eva, Thurmond Amy, Edelman Alison, Fu Rongwei, Lambert William, Seguin Jacqueline, Jensen Jeffrey T

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

The objective was to determine if intrauterine pressure can distinguish bilateral tubal occlusion (BTO) from unilateral or bilateral tubal patency (TP) in women following a permanent contraception procedure.

STUDY

DESIGN

We used a small inline pressure sensor to continuously monitor intrauterine pressure during hysterosalpingogram (HSG) in a cross-sectional study that enrolled women having HSGs for any indication. The primary outcome was the peak intrauterine pressure compared between women with BTO and TP as verified by HSG.

RESULTS

We enrolled 150 subjects, of which 111 (74.0%) provided usable pressure readings. Of these, 98/111 (88.3%) had TP, and 13 (11.7%) had BTO. There was no difference in peak intrauterine pressure for subjects with TP (mean 293.8±58.7 mmHg) compared to those with BTO (292.7±71.3 mmHg, p=.95). Among parous women, peak intrauterine pressure in subjects with BTO (311.9±78.0 mmHg) was higher but not significantly different from subjects with TP (282.7±49.2 mmHg, p=.20). In linear regression analysis, peak intrauterine pressure was not associated with age, body mass index, gravidity or having at least one prior live birth.

CONCLUSIONS

Measurement of peak intrauterine pressure does not distinguish between women with patent and blocked fallopian tubes. This approach would not be clinically useful to verify occlusion following permanent contraception.

IMPLICATIONS: Peak intrauterine pressure does not differ between women with patent and occluded fallopian tubes and cannot be used to confirm tubal occlusion after nonsurgical permanent contraception.

Для цитирования: Patil Eva, Thurmond Amy, Edelman Alison, Fu Rongwei, Lambert William, Seguin Jacqueline, Jensen Jeffrey T. Pressure dynamics in the non-gravid uterus: intrauterine pressure cannot confirm tubal occlusion after non-surgical permanent contraception.. Contraception. 2017. DOI: 10.1016/j.contraception.2017.06.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.