The Journal of prosthetic dentistry · 2023

Effect of denture cleansers on the physical and mechanical properties of CAD-CAM milled and 3D printed denture base materials: An in vitro study.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Hanno Kenda I, Abdul-Monem Mohamed M

Аннотация

STATEMENT OF PROBLEM: Studies on the impact of denture cleansers on the physical and mechanical properties of denture bases designed and constructed by using computer software programs are lacking.

PURPOSE: The purpose of this in vitro study was to test the effect of a peroxide denture cleanser on the hardness, fracture toughness, water sorption, and solubility of denture base materials manufactured by 3D printing and computer-aided design and computer-aided manufacturing (CAD-CAM) milling.

MATERIAL AND METHODS: The hardness, fracture toughness, water solubility, and sorption of CAD-CAM milled and 3D printed groups (n=40) were evaluated before and after exposure to a denture cleanser. Hardness (n=10) was analyzed with a Vickers hardness testing machine, and fracture toughness (n=20) with the 3-point bend test. After the fracture of specimens, a scanning electron microscope at ×300 was used for fractographic analysis. Water sorption and solubility (n=10) were evaluated before and after immersion in denture cleanser for 6 days to simulate 180 days of immersion. Two-way repeated ANOVA and 2-way ANOVA were used to test normally distributed data, whereas the Mann Whitney U test and Wilcoxon signed ranks test were used for data that were not normally distributed (α<.05).

RESULTS: The Vickers hardness and fracture toughness of both materials decreased after immersion in denture cleansers, with a higher decrease in values for the 3D printed group (P<.001). The denture cleanser had no effect on the water sorption and solubility of either group.

CONCLUSIONS: Milled specimens had higher hardness values and fracture toughness before and after immersion in the denture cleanser. Denture cleansers resulted in the reduced hardness and fracture toughness of both groups, but the percentage change in the milled group was lower. Denture cleansers had no effect on water sorption or solubility.