Effect of drysuit seals on intraocular pressure in non-immersed scuba divers.
Аннотация
OBJECTIVE
This study quantifies the change in intraocular pressure (IOP) secondary to wearing neck seals in scuba diving drysuits. Previous work demonstrates significant pressures exerted by these seals; we hypothesize that they would.
METHODS
IOP was measured in 33 divers before and while wearing a drysuit using rebound tonometry. The drysuit neck seal pressures were measured using a manometer. A paired two-sample t-test was used to compare IOP before and after drysuit donning. Pearson correlation coefficients were calculated between neck sealing pressures and IOP by side.
RESULTS
The mean IOP in the right eye was similar pre- and post-drysuit donning, with baseline mean 15.9 mmHg (3.7 mmhg) versus 15.4 mmHG (4.3 mmHg) post-donning, p=0.41. Similarly, the mean IOP in the left eye was also similar, with mean pre-donning IOP 15.6 (3.8 mmHg) versus 15.4 mmHg (4.7 mmHg) post-donning, p=0.75. The mean right and left neck seal pressures were 23.66 (10.60) mmHg and 23.67 (7.87) mmHg, respectively. Only the correlation between right neck sealing pressure for silicone neck seals and right IOP, pre- and post-donning was significant (pre: 0.97, p-value 0.03, post: 0.98, p-value 0.02).
CONCLUSION
No significant difference overall was detected in IOP with drysuit donning.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.