Itoh Kaku
Аннотация
PURPOSE: To evaluate the stainability of several acrylic intraocular lens (IOLs) with Brilliant Blue G (BBG) in vitro.
DESIGN: Clinically relevant, laboratory, experimental study.
METHODS: LS313MF15 as a hydrophilic acrylic IOL and X-70, W60R, CP2.2R, YP2.2R, XC1, and XY1 as hydrophobic acrylic IOLs were included in this study. Prepared acrylic IOLs were evaluated for staining via immersion for different periods in BBG solution with adjusted concentrations. In cases where IOLs were stained blue, the sustained release of BBG and IOL cross-sectional images were evaluated, as well as changes in the optical properties of the IOLs via spectrophotometry.
RESULTS: All acrylic IOLs were stained with BBG in a BBG concentration- and staining time-dependent manner, with almost no sustained release of BBG observed. Lenses with a higher water content exhibited more pronounced staining, and BBG penetrated into the IOLs. A decrease in light transmittance with a peak wavelength of 610 to 620 nm was observed in blue-stained IOLs. LS313MF15 was markedly blue stained even with a short period of staining.
CONCLUSIONS: Any acrylic IOL can be stained with BBG, but hydrophilic IOLs are particularly susceptible to blue staining. Precautions should be taken in surgeries requiring the use of BBG staining, and efforts should be made to ensure that BBG components are sufficiently washed out intraoperatively.
DESIGN: Clinically relevant, laboratory, experimental study.
METHODS: LS313MF15 as a hydrophilic acrylic IOL and X-70, W60R, CP2.2R, YP2.2R, XC1, and XY1 as hydrophobic acrylic IOLs were included in this study. Prepared acrylic IOLs were evaluated for staining via immersion for different periods in BBG solution with adjusted concentrations. In cases where IOLs were stained blue, the sustained release of BBG and IOL cross-sectional images were evaluated, as well as changes in the optical properties of the IOLs via spectrophotometry.
RESULTS: All acrylic IOLs were stained with BBG in a BBG concentration- and staining time-dependent manner, with almost no sustained release of BBG observed. Lenses with a higher water content exhibited more pronounced staining, and BBG penetrated into the IOLs. A decrease in light transmittance with a peak wavelength of 610 to 620 nm was observed in blue-stained IOLs. LS313MF15 was markedly blue stained even with a short period of staining.