MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00421-023-05265-6

Медицинская библиотека · European journal of applied physiology · 2023

Energetic responses of head-out water immersion at different temperatures during post-exercise recovery and its consequence on anaerobic mechanical power.

Coertjens Marcelo, Coertjens Patricia Chaves, Tartaruga Marcus Peikriszwili, Gorski Tatiane, Lima-Silva Adriano Eduardo, Carminatti Lorival José, Beyer Paulo Otto, de Almeida Ana Paula Viola, Geremia Jeam Marcel, Peyré-Tartaruga Leonardo Alexandre, Kruel Luiz Fernando Martins

СтатьяПеревод в очереди

Аннотация

PURPOSE: While exercise recovery may be beneficial from a physiological point of view, it may be detrimental to subsequent anaerobic performance. To investigate the energetic responses of water immersion at different temperatures during post-exercise recovery and its consequences on subsequent anaerobic performance, a randomized and controlled crossover experimental design was performed with 21 trained cyclists.

METHOD: Participants were assigned to receive three passive recovery strategies during 10 min after a Wingate Anaerobic Test (WAnT): control (CON: non-immersed condition), cold water immersion (CWI: 20 ℃), and hot water immersion (HWI: 40 ℃). Blood lactate, cardiorespiratory, and mechanical outcomes were measured during the WAnT and its recovery. Time constant (τ), asymptotic value, and area under the curve (AUC) were quantified for each physiologic parameter during recovery. After that, a second WAnT test and 10-min recovery were realized in the same session.

RESULTS

Regardless the water immersion temperature, water immersion increased [Formula: see text] (+ 18%), asymptote ([Formula: see text]+ 16%, [Formula: see text] + 13%, [Formula: see text] + 17%, HR + 16%) and AUC ([Formula: see text]+ 27%, [Formula: see text] + 18%, [Formula: see text] + 20%, HR + 25%), while decreased [Formula: see text] (- 33%). There was no influence of water immersion on blood lactate parameters. HWI improved the mean power output during the second WAnT (2.2%), while the CWI decreased 2.4% (P < 0.01).

CONCLUSION

Independent of temperature, water immersion enhanced aerobic energy recovery without modifying blood lactate recovery. However, subsequent anaerobic performance was increased only during HWI and decreased during CWI. Despite higher than in other studies, 20 °C effectively triggered physiological and performance responses. Water immersion-induced physiological changes did not predict subsequent anaerobic performance.

Для цитирования: Coertjens Marcelo, Coertjens Patricia Chaves, Tartaruga Marcus Peikriszwili, Gorski Tatiane, Lima-Silva Adriano Eduardo, Carminatti Lorival José, Beyer Paulo Otto, de Almeida Ana Paula Viola, Geremia Jeam Marcel, Peyré-Tartaruga Leonardo Alexandre, Kruel Luiz Fernando Martins. Energetic responses of head-out water immersion at different temperatures during post-exercise recovery and its consequence on anaerobic mechanical power.. European journal of applied physiology. 2023. DOI: 10.1007/s00421-023-05265-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.