Revista brasileira de cirurgia cardiovascular : orgao oficial da Sociedade Brasileira de Cirurgia Cardiovascular · 2012
Comparative experimental study of myocardial protection with crystalloid solutions for heart transplantation.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Lima Melchior Luiz, Fiorelli Alfredo Inácio, Vassallo Dalton Valentim, Pinheiro Bruno Botelho, Stolf Noedir Antonio Groppo, Gomes Otoni Moreira
Аннотация
BACKGROUND: There is a growing need to improve myocardial protection, which will lead to better performance of cardiac operations and reduce morbidity and mortality. Therefore, the objective of this study was to compare the efficacy of myocardial protection solution using both intracellular and extracellular crystalloid type regarding the performance of the electrical conduction system, left ventricular contractility and edema, after being subjected to ischemic arrest and reperfusion.
METHODS: Hearts isolated from male Wistar (n=32) rats were prepared using Langendorff method and randomly divided equally into four groups according the cardioprotective solutions used Krebs-Henseleit-Buffer (KHB), Bretschneider-HTK (HTK), St. Thomas-1 (STH-1) and Celsior (CEL). After stabilization with KHB at 37ºC, baseline values (control) were collected for heart rate (HR), left ventricle systolic pressure (LVSP), maximum first derivate of rise left ventricular pressure (+dP/dt), maximum first derivate of fall left ventricular pressure (-dP/dt) and coronary flow (CF). The hearts were then perfused at 10ºC for 5 min and kept for 2 h in static ischemia at 20ºC in each cardioprotective solution. Data evaluation was done using analysis of variance in completely randomized One-Way ANOVA and Tukey's test for multiple comparisons. The level of statistical significance chosen was P<0.05.
RESULTS: HR was restored with all the solutions used. The evaluation of left ventricular contractility (LVSP, +dP/ dt and -dP/dt) showed that treatment with CEL solution was better compared to other solutions. When analyzing the CF, the HTK solution showed better protection against edema.
CONCLUSION: Despite the cardioprotective crystalloid solutions studied are not fully able to suppress the deleterious effects of ischemia and reperfusion in the rat heart, the CEL solution had significantly higher results followed by HTK>KHB>STH-1.
METHODS: Hearts isolated from male Wistar (n=32) rats were prepared using Langendorff method and randomly divided equally into four groups according the cardioprotective solutions used Krebs-Henseleit-Buffer (KHB), Bretschneider-HTK (HTK), St. Thomas-1 (STH-1) and Celsior (CEL). After stabilization with KHB at 37ºC, baseline values (control) were collected for heart rate (HR), left ventricle systolic pressure (LVSP), maximum first derivate of rise left ventricular pressure (+dP/dt), maximum first derivate of fall left ventricular pressure (-dP/dt) and coronary flow (CF). The hearts were then perfused at 10ºC for 5 min and kept for 2 h in static ischemia at 20ºC in each cardioprotective solution. Data evaluation was done using analysis of variance in completely randomized One-Way ANOVA and Tukey's test for multiple comparisons. The level of statistical significance chosen was P<0.05.
RESULTS: HR was restored with all the solutions used. The evaluation of left ventricular contractility (LVSP, +dP/ dt and -dP/dt) showed that treatment with CEL solution was better compared to other solutions. When analyzing the CF, the HTK solution showed better protection against edema.
CONCLUSION: Despite the cardioprotective crystalloid solutions studied are not fully able to suppress the deleterious effects of ischemia and reperfusion in the rat heart, the CEL solution had significantly higher results followed by HTK>KHB>STH-1.
Предметные рубрики MeSH
Analysis of VarianceAnimalsBicarbonatesCalcium ChlorideCardioplegic SolutionsCrystalloid SolutionsDisaccharidesEdema, CardiacElectrolytesGlucoseGlutamatesGlutathioneHeart Arrest, InducedHeart Conduction SystemHeart TransplantationHemodynamicsHistidineIsotonic SolutionsMagnesiumMaleMannitolModels, AnimalMyocardial ContractionMyocardial Reperfusion InjuryOrgan PreservationPotassium ChlorideProcaineRandom AllocationRatsRats, WistarSodium ChlorideTromethamineVentricular Function, Left