MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-0043-121882

Медицинская библиотека · Endoscopy international open · 2018

Novel experimental and software methods for image reconstruction and localization in capsule endoscopy.

Koulaouzidis Anastasios, Iakovidis Dimitris K, Yung Diana E, Mazomenos Evangelos, Bianchi Federico, Karagyris Alexandros, Dimas George, Stoyanov Danail, Thorlacius Henrik, Toth Ervin, Ciuti Gastone

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND STUDY AIMS: Capsule endoscopy (CE) is invaluable for minimally invasive endoscopy of the gastrointestinal tract; however, several technological limitations remain including lack of reliable lesion localization. We present an approach to 3D reconstruction and localization using visual information from 2D CE images.

PATIENTS AND

METHODS

Colored thumbtacks were secured in rows to the internal wall of a LifeLike bowel model. A PillCam SB3 was calibrated and navigated linearly through the lumen by a high-precision robotic arm. The motion estimation algorithm used data (light falling on the object, fraction of reflected light and surface geometry) from 2D CE images in the video sequence to achieve 3D reconstruction of the bowel model at various frames. The ORB-SLAM technique was used for 3D reconstruction and CE localization within the reconstructed model. This algorithm compared pairs of points between images for reconstruction and localization.

RESULTS

As the capsule moved through the model bowel 42 to 66 video frames were obtained per pass. Mean absolute error in the estimated distance travelled by the CE was 4.1 ± 3.9 cm. Our algorithm was able to reconstruct the cylindrical shape of the model bowel with details of the attached thumbtacks. ORB-SLAM successfully reconstructed the bowel wall from simultaneous frames of the CE video. The "track" in the reconstruction corresponded well with the linear forwards-backwards movement of the capsule through the model lumen.

CONCLUSION

The reconstruction methods, detailed above, were able to achieve good quality reconstruction of the bowel model and localization of the capsule trajectory using information from the CE video and images alone.

Для цитирования: Koulaouzidis Anastasios, Iakovidis Dimitris K, Yung Diana E, Mazomenos Evangelos, Bianchi Federico, Karagyris Alexandros, Dimas George, Stoyanov Danail, Thorlacius Henrik, Toth Ervin, Ciuti Gastone. Novel experimental and software methods for image reconstruction and localization in capsule endoscopy.. Endoscopy international open. 2018. DOI: 10.1055/s-0043-121882.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.