m+Medelevator.RU
← Поиск публикаций
Contraception · 2024

Health-related quality of life and satisfaction associated with 3-year use of a levonorgestrel 13.5 mg intrauterine device vs Nova T copper 380 mm2 intrauterine device: Results of a phase 4 randomized controlled trial.

Рандомизированное исследованиеКлиническое исследование IV фазыСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Perelló-Capó Josep, Estadella-Tarriel Josep, Gich-Saladich Ignasi, Bailón-Queiruga Marta, Llurba-Olivé Elisa, Calaf-Alsina Joaquim

Аннотация

OBJECTIVES: This study aimed to investigate the impact of levonorgestrel 13.5 mg and Nova T copper 380 mm2 intrauterine devices (LNG13.5-IUD and Cu380-IUD, respectively) on health-related quality of life (HRQoL) and the satisfaction with the method throughout 3 years of use.

STUDY DESIGN: We conducted a single-center, evaluator-masked, randomized controlled trial to compare the bleeding profile of LNG13.5-IUD and Cu380-IUD users. Secondary objectives included HRQoL and satisfaction throughout the study. We used the validated questionnaire of the Spanish Society of Contraception (SEC-QoL), which evaluates social, sexual/psychological well-being, and menstrual/breast symptoms, to assess HRQoL and a 5-point Likert scale for satisfaction.

RESULTS: These secondary outcomes were assessed in the whole population included in the study: 55 LNG13.5-IUD and 51 Cu380-IUD users. The mean overall SEC-QoL scores were similar at baseline (61.5 and 59.6, respectively; p = 0.570) and greater for LNG13.5-IUD after 3 years (69.2 vs 52.5, respectively; p = 0.002). All SEC-QoL domains scored also higher (p < 0.05 vs Cu380-IUD for all). At month 36, 20/30 (67%) and 8/28 (29%) users, respectively, had reached the MID (a 3.4-point increase) in SEC-QoL score (p = 0.004). At this time, 24/29 (82%) and 9/28 (32%) users, respectively, were "very satisfied" (p < 0.001). Willingness to continue the method was similar (22/28 [79%] vs 17/28 [61%] users, respectively; p = 0.170).

CONCLUSIONS: Among the use of LNG13.5-IUD was associated with better HRQoL vs Cu380-IUD throughout the 3 years. Satisfaction with the method was higher with LNG13.5-IUD.

IMPLICATIONS: People considering having an LNG13.5-IUD or a Cu380-IUD inserted may now benefit from the information regarding the impact of these devices on HRQoL and satisfaction with the method as reported in our study conducted in Spain.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты