MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.contraception.2024.110362

Медицинская библиотека · Contraception · 2024

Longitudinal impact of a residency-based postplacental levonorgestrel intrauterine device insertion program: Expulsion rates in years 1, 2, and 3.

Free Leanne L, Brown Benjamin P, Matteson Kristen A, Cronin Beth, Has Phinnara, Zeyl Victoria, Allen Rebecca H

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To evaluate expulsion rates in the first 3 years of an academic postplacental levonorgestrel intrauterine device (LNG-IUD) insertion program.

STUDY

DESIGN

Retrospective case series, January 2016 to December 2018. We measured LNG-IUD expulsion rates by 12 weeks postpartum.

RESULTS

Of 235 LNG-IUD insertions, in years 1, 2, and 3, expulsion rates were 11/39 (28%), 9/94 (10%), and 15/102 (15%) (p = 0.03). After vaginal delivery, manual insertion was associated with a higher expulsion rate than ring-forceps (10/28 [36%] vs 17/105 [16%], p = 0.04).

CONCLUSIONS

LNG-IUD expulsion rates decreased after program year 1, suggesting program maturity may be associated with a lower expulsion risk.

Для цитирования: Free Leanne L, Brown Benjamin P, Matteson Kristen A, Cronin Beth, Has Phinnara, Zeyl Victoria, Allen Rebecca H. Longitudinal impact of a residency-based postplacental levonorgestrel intrauterine device insertion program: Expulsion rates in years 1, 2, and 3.. Contraception. 2024. DOI: 10.1016/j.contraception.2024.110362.