DOI 10.1016/j.contraception.2014.02.004
Obstetrician-gynecologists and contraception: long-acting reversible contraception practices and education.
Аннотация
OBJECTIVES
Long-acting reversible contraception (LARC) - the copper and levonorgestrel intrauterine devices (IUDs) and the single-rod implant - are safe and effective but account for a small proportion of contraceptive use by US women. This study examined obstetrician-gynecologists' knowledge, training, practice and beliefs regarding LARC methods.
DESIGN
A survey questionnaire was mailed to 3000 Fellows of the American College of Obstetricians and Gynecologists. After exclusions, 1221 eligible questionnaires were analyzed (45.8% response rate, accounting for exclusions).
RESULTS
Almost all obstetrician-gynecologists reported providing IUDs (95.8%). Most obstetrician-gynecologists reported requiring two or more visits for IUD insertion (86.9%). Respondents that reported IUD insertion in a single visit reported inserting a greater number of IUDs in the last year. About half reported offering the single-rod implant (51.3%). A total of 92.0% reported residency training on IUDs, and 50.8% reported residency training on implants. Residency training and physician age correlated with the number of IUDs inserted in the past year. A total of 59.6% indicated receiving continuing education on at least one LARC method in the past 2years. Recent continuing education was most strongly associated with implant insertion, and 31.7% of respondents cited lack of insertion training as a barrier.
CONCLUSIONS
Barriers to LARC provision could be reduced if more obstetrician-gynecologists received implant training and provided same-day IUD insertion. Continuing education will likely increase implant provision.
IMPLICATIONS: This study shows that obstetrician-gynecologists generally offer IUDs, but fewer offer the single-rod contraceptive implant. Recent continuing education strongly predicted whether obstetrician-gynecologists inserted implants and was also associated with other practices that encourage LARC use.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.