Computed tomography before balloon Eustachian tuboplasty--a true necessity?

Abdel-Aziz Tarek, Schröder Stefanie, Lehmann Martin, Gehl Hans-Björn, Ebmeyer Jörg, Sudhoff Holger

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Since the introduction of balloon Eustachian tuboplasty the necessity of preoperative high-resolution CT scans of the temporal bone has been a topic of debate. This study investigated the informative value of preoperative CT scanning in predicting intraoperative or postoperative difficulties and complications. Special focus was laid on the existence of carotid canal dehiscences for fear of intraprocedural injury.

STUDY

DESIGN

Retrospective.

SETTING

Tertiary referral center.

PATIENTS AND INTERVENTIONS: Approximately 284 patients (510 Eustachian tubes) with intractable Eustachian tube dysfunction undergoing unilateral or bilateral balloon Eustachian tuboplasty with preoperative high-resolution CT scans of the temporal bone from January 1, 2009, to December 31, 2012.

RESULTS

Carotid canal dehiscences were found in 18 patients (6.3%). In 3 patients (4 Eustachian tubes, 1.1% of patients) balloon dilatation could not be performed because of difficulties advancing the balloon catheter. Of these 3 patients, one had bilateral carotid canal dehiscences, whereas the other two had unremarkable CT scans. Postoperative complications occurred in 3 patients (1.1%): 2 soft tissue emphysemas and 1 unilateral hypoglossal paresis. All 3 patients had unremarkable CT scans, and all complications resolved completely without further sequelae.

CONCLUSION

Preoperative high-resolution CT scan of the temporal bone does not seem to be suitable to predict intraoperative or postoperative difficulties of balloon Eustachian tuboplasty. Being extremely cautious during balloon catheter insertion into the Eustachian tube and using a device that is designed with a built-in stop mechanism preventing too deep insertion, the data presented suggest that fear of injury to the internal carotid artery during balloon dilatation might be disproportionate. Nevertheless, for inexperienced surgeons, HR-CT scans of the temporal bone may help to understand the relation between internal carotid artery and the Eustachian tube.

Для цитирования: Abdel-Aziz Tarek, Schröder Stefanie, Lehmann Martin, Gehl Hans-Björn, Ebmeyer Jörg, Sudhoff Holger. Computed tomography before balloon Eustachian tuboplasty--a true necessity?. Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 2014. DOI: 10.1097/mao.0000000000000214.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.