DOI 10.1097/mao.0000000000000214
Computed tomography before balloon Eustachian tuboplasty--a true necessity?
Аннотация
OBJECTIVE
Since the introduction of balloon Eustachian tuboplasty the necessity of preoperative high-resolution CT scans of the temporal bone has been a topic of debate. This study investigated the informative value of preoperative CT scanning in predicting intraoperative or postoperative difficulties and complications. Special focus was laid on the existence of carotid canal dehiscences for fear of intraprocedural injury.
STUDY
DESIGN
Retrospective.
SETTING
Tertiary referral center.
PATIENTS AND INTERVENTIONS: Approximately 284 patients (510 Eustachian tubes) with intractable Eustachian tube dysfunction undergoing unilateral or bilateral balloon Eustachian tuboplasty with preoperative high-resolution CT scans of the temporal bone from January 1, 2009, to December 31, 2012.
RESULTS
Carotid canal dehiscences were found in 18 patients (6.3%). In 3 patients (4 Eustachian tubes, 1.1% of patients) balloon dilatation could not be performed because of difficulties advancing the balloon catheter. Of these 3 patients, one had bilateral carotid canal dehiscences, whereas the other two had unremarkable CT scans. Postoperative complications occurred in 3 patients (1.1%): 2 soft tissue emphysemas and 1 unilateral hypoglossal paresis. All 3 patients had unremarkable CT scans, and all complications resolved completely without further sequelae.
CONCLUSION
Preoperative high-resolution CT scan of the temporal bone does not seem to be suitable to predict intraoperative or postoperative difficulties of balloon Eustachian tuboplasty. Being extremely cautious during balloon catheter insertion into the Eustachian tube and using a device that is designed with a built-in stop mechanism preventing too deep insertion, the data presented suggest that fear of injury to the internal carotid artery during balloon dilatation might be disproportionate. Nevertheless, for inexperienced surgeons, HR-CT scans of the temporal bone may help to understand the relation between internal carotid artery and the Eustachian tube.