MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.anireprosci.2024.107518

Медицинская библиотека · Animal reproduction science · 2024

Inter-software reliability and agreement for follicular and luteal morphometric and echotextural ultrasonographic parameters in beef cattle.

Pinzón-Osorio César Augusto, Machado Marco Alves, Camozzato Julia Nobre Blank, Dos Santos Velho Gabriella, Dalto André Gustavo Cabrera, Rovani Monique Tomazele, de Oliveira Fernando Caetano, Bertolini Marcelo

СтатьяПеревод в очереди

Аннотация

This study aimed to compare the inter-software and inter-observer reliability and agreement for the assessment of follicular and luteal morphometry and echotexture parameters in beef crossbreed females (3/8 Bos taurus indicus and 5/8 Bos taurus taurus). B-mode and color Doppler ultrasonographic ovarian images were obtained at specific time points of estradiol-progesterone-based protocols for timed artificial insemination (TAI). Sonograms were analyzed by two observers using a licensed (IASP1) and an open access (IASP2) software package. A total of 292 snap-shot sonograms were analyzed for morphometric parameters and 504 for echotexture parameters. inter-software reliability was judged moderate to excellent (ICC or CCC=0.73-0.98), whereas inter-observer reliability for morphometric parameters was deemed good to excellent (ICC or CCC=0.82-0.98). A small percentage (up to 10.95 %) of measured parameters fell outside the limits of inter-software and inter-observer agreement. For echotexture parameters, inter-software reliability varied widely (ICC or CCC=0.16-0.95) based on the size of regions of interest (ROI), while inter-observer reliability ranged from moderate to excellent (ICC or CCC= 0.71-0.97). The highest inter-software reliability for pixel value and heterogeneity value was observed for the corpus luteum (ICCs=0.81-0.95; P>0.05), followed by the peripheral follicular antrum (ICCs=0.75-0.78; P<0.05). However, lower reliability was determined for the follicular wall (ICCs=0.08-0.33; P<0.0001) and perifollicular stroma (ICCs=0.16-0.46; P<0.05). In conclusion, both software packages showed high reproducibility for morphometric measurements, while echotexture measurements were more challenging to replicate based on ROI sizes. Caution is advised when selecting ROI sizes for echotexture measurements in bovine ovaries.

Для цитирования: Pinzón-Osorio César Augusto, Machado Marco Alves, Camozzato Julia Nobre Blank, Dos Santos Velho Gabriella, Dalto André Gustavo Cabrera, Rovani Monique Tomazele, de Oliveira Fernando Caetano, Bertolini Marcelo. Inter-software reliability and agreement for follicular and luteal morphometric and echotextural ultrasonographic parameters in beef cattle.. Animal reproduction science. 2024. DOI: 10.1016/j.anireprosci.2024.107518.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.