m+Medelevator.RU
← Поиск публикаций
Analytical methods : advancing methods and applications · 2026

Geometry driven machine learning guided fabrication of sub-5 µm PLGA microparticles for balloon catheter drug delivery.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ibrahim Mohamed S, Ashraf Mahmoud, Seresht Hassan Beheshti, Chupein Mia C, Kum Chang Hun, Cho Jae Hwa, Jin Gyuhyun, An Sang Hyun, Lamperski Jourdain, Wagner William R, Ye Sangho, Chun Youngjae

Аннотация

Poly (lactic-co-glycolic acid) (PLGA) microparticles are widely used as biodegradable drug-delivery carriers, where particle size critically governs drug release kinetics, degradation behavior, and overall therapeutic performance. Producing sub-5 µm PLGA microparticles in PDMS microfluidic devices remains challenging due to limited shear control, PDMS swelling in organic solvents, and instability at high flow-rate ratios. This study demonstrates stable generation of sub-5 µm PLGA microparticles by integrating a shear-modulating obstruction into a cross-junction microfluidic device to enhance droplet breakup under laminar flow. Computational Fluid Dynamics (CFD) simulations and initial experiments showed that positioning a 150 µm-wide obstruction 5 µm downstream shifted droplet formation into a stable dripping regime, reducing droplet size from 84 ± 5 µm (10 : 1) and 32 ± 3 µm (20 : 1) in the unobstructed device to 8 ± 0.7 µm with controlled pinch-off, followed by a machine-learning-guided optimization model to identify parameter combinations that yielded 3.6-4.5 µm microparticles under optimized conditions. A Polynomial Regression surrogate model in a machine learning-assisted optimization accurately captured nonlinear interactions between flow-rate ratio, obstruction width, and obstruction distance. Coupling the model with randomized grid search (n = 2000) yielded design combinations that experimentally reproduced particle sizes within <3% error for four of five candidate models. Finally, a thermoresponsive biodegradable polymer adhesive enabled temperature-activated attachment of the unloaded PLGA microparticles to a coronary balloon catheter and partial particle transfer during balloon inflation in a simplified silicone arterial model, providing an enabling platform for future catheter-based drug-delivery studies.

Предметные рубрики MeSH