MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Cryo letters · 2022

Effects of cell concentration during cryopreservation on the post-thaw quality of Santa ines ram sperm.

de Oliveira M B, Jeri Molina J C, da Silva R S, Ramos A F, Purdy P H, Azevedo H C

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Non-surgical artificial insemination techniques for sheep may benefit from larger numbers of sperm in the insemination dose because the ewe cervix is convoluted and often cannot be traversed with an insemination gun resulting in deposition of the sperm at the os cervix.

OBJECTIVE

To compare a range of sperm concentrations when cryopreserving semen from Santa Ines rams and determine the effects of this on post-thaw quality.

MATERIALS AND

METHODS

One ejaculate from each ram (n = 10) was diluted to four sperm concentrations to obtain the following groups: G-400, G-800, G-1200, and G-1600 x 106 sperm/mL. The semen samples were packaged in 0.25 mL straws, cooled to 5 degree C, cryopreserved in liquid nitrogen vapor, thawed in a water bath (40 degree C per 20 s), and were analyzed for computerized kinetics, capacitation and acrosome integrity, and plasma membrane integrity of sperm.

RESULTS

The G-400 treatment resulted in samples with the highest linearity and progressive motion (P < 0.05) and had significantly greater plasma membrane integrity, and lower capacitation and acrosome reaction rates compared to G-1600 (P < 0.05). Overall, use of the G-400 treatment resulted in better kinetics, less plasma membrane damage and less early capacitation. However, despite reducing the ejaculate yield and increasing the costs of the semen freezing process, the G-800 and G-1200 treatments make a greater absolute number of sperm with good kinetics, plasma membrane integrity and capacitation status available.

CONCLUSION

Ram sperm concentration impacts cryopreservation, and higher concentrations may be advantageous if a single artificial insemination protocol is desirable. doi.org/10.54680/fr22610110812.

Для цитирования: de Oliveira M B, Jeri Molina J C, da Silva R S, Ramos A F, Purdy P H, Azevedo H C. Effects of cell concentration during cryopreservation on the post-thaw quality of Santa ines ram sperm.. Cryo letters. 2022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.