Grating based laboratory 5.41 keV X-ray phase contrast microscopy with zone-plate: design, instrumentation and validation.
СтатьяВалидационное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Tan Yuhang, Yang Jiecheng, Zhu Jiongtao, Zhang Xin, Zheng Hairong, Liang Dong, Li Zhicheng, Ge Yongshuai
Аннотация
BackgroundIt has been demonstrated that grating interferometers can be utilized to enhance the X-ray imaging contrast of low-density and weakly absorbing objects.ObjectiveIn this study, the design, instrumentation and validation of a grating based laboratory 5.41 keV X-ray phase-contrast microscope with zone-plate are reported.MethodsThis dedicated microscope was carefully designed by coupling the zone-plate imaging method and the grating interferometer imaging method. Specially fabricated X-ray optics were integrated along with a certain X-ray tube source illumination module, motion stages and X-ray detection module. The system's spatial resolution was characterized with the modulation transfer function (MTF) analysis and the power spectral density (PSD) analysis. The absorption-contrast and phase-contrast images were extracted from the acquired phase stepping dataset. The splitting and superposition behavior of the phase-contrast signal was evaluated by comparing the experimental results with the numerical simulation. CT projections of a mitochondria-targeted, antibody-stained Jurkat T cell were pre-processed by geometric registration before performing the standard filtered back-projection (FBP) reconstruction.ResultsThe absorption imaging results of the Siemens star phantom demonstrated that this microscope achieved a spatial resolution of 35.0 nm based on MTF analysis, while the minimum detectable structure size was 28.5 nm based on PSD analysis. The phase-contrast imaging of a 5.00μm diameter polystyrene microsphere demonstrated the splitting phenomenon (8.54μm on the sample plane) of the ±1st order components, and both the splitting distance and line profiles agreed well with the theoretical imaging model. In the reconstructed phase-contrast CT images, the mitochondria could be clearly identified.ConclusionsThis study reported the development of a grating based laboratory 5.41 keV X-ray phase-contrast microscope with zone-plate. Results showed that it could significantly enhance the imaging performance of low-density objects such as polystyrene microsphere and biological cells.