MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/tnsre.2026.3710674

Медицинская библиотека · IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2026

Evaluation of a Portable EMG-Controlled Hand Exoskeleton With Independent Digit Actuation.

Ghassemi Mohammad, Vogel Christopher M, Sprague Alexander H, Kamper Derek G

СтатьяОценочное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Despite therapeutic efforts, the majority of individuals post-stroke will experience chronic motor deficits, particularly in the hand. Assistive devices such as hand exoskeletons have the potential to improve hand function, but these instruments must provide sufficient flexibility to support a variety of tasks. This study tests the robustness and utility of a novel device, the Bidirectionally Actuated Cable (BAC)-Glove, which provides independent actuation of each digit. The BAC-Glove supports a variety of control modes, including direct user control through electromyography (EMG).

METHODS

Device capabilities in terms of digit movement and fingertip force production were assessed in 5 neurotypical participants. Kinematics were captured with motion tracking and kinetics were captured with a load cell. Another 10 neurotypical participants completed four training sessions with the BAC-Glove to examine the viability of EMG control. Evaluations were performed at the end of the first and last sessions to examine user performance with the device.

RESULTS

The device produced coordinated flexion and extension motions of all three finger joints and peak fingertip forces of 15.1 N in flexion and 9.6 N in extension. Participants improved EMG control of the BAC-Glove over the training sessions, as evidenced by significant improvement on measures of object manipulation with the device, such as the Box and Block test (p < 0.05).

CONCLUSIONS

BAC-Glove is a robust and potentially useful device for assisting manipulation of objects to perform activities of daily living. The proposed EMG control scheme showed sufficient viability to warrant future examination in clinical populations.

Для цитирования: Ghassemi Mohammad, Vogel Christopher M, Sprague Alexander H, Kamper Derek G. Evaluation of a Portable EMG-Controlled Hand Exoskeleton With Independent Digit Actuation.. IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society. 2026. DOI: 10.1109/tnsre.2026.3710674.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.