MedElevator Войти в исследования
← Поиск публикаций

DOI 10.64898/2026.05.29.26354454

Медицинская библиотека · medRxiv : the preprint server for health sciences · 2026

Preliminary Reliability and Validity of SynapTrack, a Smartphone-Based Digital Biomarker Platform for Remote Assessment of Cervical Spondylotic Myelopathy.

Yakdan Salim, Singh Pranay, Arkam Faraz, Chen Erdong, Lewis Abigail, Steel Benjamin, Becker Isaac, Guo Wenwen, Naveed Haris, Wang Carl, Yang Deyuan, Wang Zhuoran, Ray Wilson Z, Hassenstab Jason, Steinmetz Michael P, Ghogawala Zoher, Kelleher Caitlin, Greenberg Jacob K

СтатьяПрепринтПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVES

Cervical spondylotic myelopathy (CSM) is a leading cause of neurological disability in older adults. However, validated, scalable tools to quantify disease severity and changes over time are lacking. Recent advances in smartphone technology have opened new avenues for longitudinal, objective, and remote monitoring of neurological conditions. We performed a preliminary evaluation of the reliability and validity of SynapTrack, a smartphone-based digital platform for objective remote CSM assessments.

METHODS

In this single-center prospective cohort study, 251 participants (151 with CSM, 100 healthy controls) completed in-person SynapTrack assessments related to tapping, pinching, and vibratory detection, along with reference laboratory measures of dexterity (Box and Block Test, 9-Hole Peg Test) and vibratory sensation (tuning fork). A subset completed repeated home-based testing to assess test-retest reliability. We evaluated convergent validity, construct validity against the modified Japanese Orthopedic Association (mJOA) score, known-groups validity, and test-retest reliability (intraclass correlation coefficient, ICC).

RESULTS

Smartphone-derived metrics demonstrated good-to-excellent test-retest reliability, with the strongest stability for vibratory detection threshold (ICC = 0.92), overall and non-dominant tapping speed (ICC = 0.90 each), and pinching successful targets (ICC = 0.90). Convergent validity was supported by moderate-to-strong correlations between digital metrics and reference laboratory dexterity tests (ρ up to 0.60 for tapping speed; up to -0.65 for the vibratory threshold). Construct validity against the mJOA was strongest for the vibratory threshold (ρ = -0.53 to -0.54) and Level 2 non-dominant pinching errors (ρ = -0.45). Selected metrics distinguished CSM patients from controls with good discrimination, including non-dominant tapping speed (AUROC = 0.76, 95% CI 0.68-0.85), Level 2 dominant pinching successful targets (AUROC = 0.78, 95% CI 0.62-0.94), and the non-dominant vibratory threshold (AUROC = 0.77, 95% CI 0.64-0.90).

CONCLUSIONS AND RELEVANCE: A smartphone-based battery of upper-extremity sensorimotor tasks demonstrated preliminary reliability and validity in CSM. Furthermore, to our knowledge, the novel vibratory detection task represents the first smartphone-based sensory assessment used for CSM. Collectively, these findings position SynapTrack as a scalable platform for objective, remote neurological monitoring of CSM.

Для цитирования: Yakdan Salim, Singh Pranay, Arkam Faraz, Chen Erdong, Lewis Abigail, Steel Benjamin, Becker Isaac, Guo Wenwen, Naveed Haris, Wang Carl, Yang Deyuan, Wang Zhuoran, Ray Wilson Z, Hassenstab Jason, Steinmetz Michael P, Ghogawala Zoher, Kelleher Caitlin, Greenberg Jacob K. Preliminary Reliability and Validity of SynapTrack, a Smartphone-Based Digital Biomarker Platform for Remote Assessment of Cervical Spondylotic Myelopathy.. medRxiv : the preprint server for health sciences. 2026. DOI: 10.64898/2026.05.29.26354454.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.