MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/diagnostics16111705

Медицинская библиотека · Diagnostics (Basel, Switzerland) · 2026

Cross-Dataset Generalization of Deep Learning-Based Detectors for Intracranial Hemorrhage Subtype Localization on Noncontrast Head CT: A Comparative Study.

Lee Chiao-Hua, Muzakky Hikam, Juan Cheng-En, Chang Chia-Ching, Li Ya-Hui, Lee Tung-Yang, Juan Cheng-Hsuan, Tsai Ming-Ting, Juan Chun-Jung

СтатьяПеревод в очереди

Аннотация

Background/

Objectives

To evaluate the effect of detector architecture and dataset characteristics on intracranial hemorrhage (ICH) subtype localization on noncontrast head CT, with emphasis on bidirectional cross-dataset generalization.

Methods

This retrospective study analyzed two publicly available datasets: the Brain Hemorrhage Extended (BHX) dataset and the RSNA 2019+ dataset. Models were trained and internally validated on one dataset and externally tested on the other dataset in both directions: BHX-to-RSNA+ and RSNA+-to-BHX. Six representative deep learning detectors, including CNN-based one-stage and two-stage detectors and a Swin Transformer-based RT-DETR (Swin-RT-DETR) variant, were evaluated. Localization performance was assessed using mean average precision at a bounding-box intersection-over-union threshold of 0.5 (mAP@50), bounding-box Dice similarity coefficient (BB-DSC), and bounding-box intersection-over-union (BB-IoU). Image-level and patient-level analyses were performed, with Bonferroni correction applied for statistical comparisons. Dataset characterization analyses were performed to compare subtype prevalence, bounding-box geometry, lesion burden, annotation density, and spatial distribution.

Results

Under internal validation, Swin-RT-DETR achieved competitive or superior performance across several ICH subtypes, but its advantage was subtype-dependent rather than uniform. Faster R-CNN with a ResNeXt101 backbone achieved comparable IVH performance and higher IPH BB-DSC and BB-IoU, whereas Swin-RT-DETR performed better for SAH, SDH, and EDH. External validation showed substantial performance degradation across architectures, subtypes, and validation directions. Absolute BB-DSC reductions for Swin-RT-DETR ranged from approximately 0.54-0.79 in the BHX-to-RSNA+ direction and 0.17-0.74 in the RSNA+-to-BHX direction. Similar degradation patterns were observed at the patient level. Statistical comparisons showed fewer significant model-level differences under external validation, suggesting attenuation of architecture-specific advantages under domain shift. Dataset characterization analysis demonstrated differences in subtype distribution, bounding-box geometry, lesion burden, annotation density, and spatial localization patterns between BHX and RSNA+.

Conclusions

ICH subtype localization performance is strongly influenced by dataset characteristics, annotation heterogeneity, and domain shift. Although Transformer-based hierarchical feature extraction showed subtype-dependent advantages under internal validation, these advantages diminished under bidirectional external validation. These findings highlight the need for dataset characterization, external validation, patient-level evaluation, and task-specific clinical benchmarks before automated ICH localization models can be considered for real-world clinical integration.

Для цитирования: Lee Chiao-Hua, Muzakky Hikam, Juan Cheng-En, Chang Chia-Ching, Li Ya-Hui, Lee Tung-Yang, Juan Cheng-Hsuan, Tsai Ming-Ting, Juan Chun-Jung. Cross-Dataset Generalization of Deep Learning-Based Detectors for Intracranial Hemorrhage Subtype Localization on Noncontrast Head CT: A Comparative Study.. Diagnostics (Basel, Switzerland). 2026. DOI: 10.3390/diagnostics16111705.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.