MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10278-026-02024-9

Медицинская библиотека · Journal of imaging informatics in medicine · 2026

Uncertainty-Aware Super-Resolution for Mammography Phantoms using a Dropout-Enabled SwinIR.

Katayama Yutaka, Hiura Shinsaku, Tanaka Rie, Saito Shigeyoshi, Ohta Yukino, Tani Wakiko, Utsunomiya Akane, Ueda Daiju

СтатьяПеревод в очереди

Аннотация

This study was aimed at presenting a framework integrating uncertainty quantification into the SwinIR super-resolution model for mammography, addressing the "black box" limitation that hinders clinical trust. Monte Carlo (MC) Dropout was incorporated into SwinIR to generate both high-resolution images and corresponding pixel-wise uncertainty maps. The framework was systematically evaluated on a standardized mammography phantom in two scenarios: a standard 4 × super-resolution task and an enhancement task applied to the original high-resolution image. In the standard task, the L1 model achieved a structural similarity index of 0.982, outperforming the bicubic interpolation baseline (0.978). The uncertainty maps revealed context-dependent behavior: low uncertainty for high-frequency structures destroyed by downsampling, high uncertainty when sharpening identifiable structures in the original image, and consistently low uncertainty for low-contrast objects. Quantitative analysis showed a near-zero correlation between absolute error and uncertainty in low-contrast regions, indicating an overconfident rate where approximately 0.3% of pixels showed high error but low uncertainty. High uncertainty does not indicate error but reflects active intervention on recognizable structures, whereas low uncertainty may represent either true stability or inaction in the face of insufficient evidence. In this phantom study, uncertainty served as a transparency tool rather than a measure of correctness. As a proof-of-concept, these findings suggest potential for enhancing interpretability, though further validation on clinical data is required to establish utility and safety in patient imaging. Source code is publicly available at https://github.com/evh-5150/DICOM_SR_Uncertainty .

Для цитирования: Katayama Yutaka, Hiura Shinsaku, Tanaka Rie, Saito Shigeyoshi, Ohta Yukino, Tani Wakiko, Utsunomiya Akane, Ueda Daiju. Uncertainty-Aware Super-Resolution for Mammography Phantoms using a Dropout-Enabled SwinIR.. Journal of imaging informatics in medicine. 2026. DOI: 10.1007/s10278-026-02024-9.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.