MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-026-48802-x

Медицинская библиотека · Scientific reports · 2026

Consistent nonlinear optical refractive index [Formula: see text] measurement of porcine crystalline lens and its surrounding in the 650-900 nm range.

Comte Vincent, Zinoune Julien Bilal, Meunier Tom, Gain Philippe, Thuret Gilles, Bessin Florent, Cassagne Christophe, Boudebs Georges, Mauclair Cyril

СтатьяПеревод в очереди

Аннотация

The nonlinear optical properties of transparent ocular media have been shown to alter the focused intensity distribution of femtosecond laser pulses, potentially affecting the precision of laser ophthalmic surgery. In this study, the nonlinear refractive index [Formula: see text] of porcine aqueous humor, crystalline lens and vitreous humor was measured using two complementary techniques: the standard Z-scan-derived D4σ method and the phase-object imaging method. Both were performed with a tunable femtosecond laser source across the visible to near-infrared range (650-900 nm). All measured [Formula: see text] values were found to be close to [Formula: see text] within experimental uncertainties, with no measurable nonlinear absorption detected. Notably, the phase-object technique proved particularly well-suited for slightly scattering or heterogeneous media, such as the freshly extracted crystalline lens, when calibrated against a reference medium (here, water). These experimental results allow for a quantitative numerical assessment of pulse and beam degradation due to nonlinear refraction during procedures like cataract surgery, as well as an evaluation of its potential impact on photodisruption geometry.

Для цитирования: Comte Vincent, Zinoune Julien Bilal, Meunier Tom, Gain Philippe, Thuret Gilles, Bessin Florent, Cassagne Christophe, Boudebs Georges, Mauclair Cyril. Consistent nonlinear optical refractive index [Formula: see text] measurement of porcine crystalline lens and its surrounding in the 650-900 nm range.. Scientific reports. 2026. DOI: 10.1038/s41598-026-48802-x.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.