MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/hbm.70462

Медицинская библиотека · Human brain mapping · 2026

segcsvdPVS: A Convolutional Neural Network-Based Tool for Quantification of Enlarged Perivascular Spaces (PVS) on T1-Weighted Images.

Gibson Erin, Ramirez Joel, Woods Lauren Abby, Berberian Stephanie, Ottoy Julie, Scott Christopher J M, Yhap Vanessa, Gao Fuqiang, Coello Roberto Duarte, Valdes Hernandez Maria, Lang Anthony E, Tartaglia Carmela M, Kumar Sanjeev, Binns Malcolm A, Bartha Robert, Symons Sean, Swartz Richard H, Masellis Mario, Singh Navneet, MacIntosh Bradley J, Wardlaw Joanna M, Black Sandra E, ONDRI Investigators, ADNI, CAHHM Investigators, CAIN Investigators, colleagues from the Foundation Leducq Transatlantic Network of Excellence, Lim Andrew S P, Goubran Maged

СтатьяПеревод в очереди

Аннотация

Enlarged perivascular spaces (PVS) are imaging markers of cerebral small vessel disease (CSVD) that are associated with age, disease phenotypes, and overall health. Quantification of PVS is challenging but necessary to expand an understanding of their role in cerebrovascular pathology. Accurate and automated segmentation of PVS on T1-weighted images would be valuable given the widespread use of T1-weighted imaging protocols in multisite clinical and research datasets. We introduce segcsvdPVS, a convolutional neural network (CNN)-based tool for automated PVS segmentation on T1-weighted images. segcsvdPVS was developed using a novel hierarchical approach that builds on existing tools and incorporates robust training strategies to enhance the accuracy and consistency of PVS segmentation. Performance was evaluated using a comprehensive evaluation strategy that included comparison to existing benchmark methods, ablation-based validation, accuracy validation against manual ground truth annotations, correlation with age-related PVS burden as a biological benchmark, and extensive robustness testing. segcsvdPVS achieved strong object-level performance for basal ganglia PVS (DSC = 0.78), exhibiting both high sensitivity (SNS = 0.80) and precision (PRC = 0.78). Although voxel-level precision was lower (PRC = 0.57), manual correction improved this by only ~3%, indicating that the additional voxels reflected primary boundary- or extent-related differences rather than correctable false positive error. For non-basal ganglia PVS, segcsvdPVS outperformed benchmark methods, exhibiting higher voxel-level performance across several metrics (DSC = 0.60, SNS = 0.67, PRC = 0.57, NSD = 0.77), despite overall lower performance relative to basal ganglia PVS. Additionally, the association between age and segmentation-derived measures of PVS burden was consistently stronger and more reliable for segcsvdPVS compared to benchmark methods across three cohorts (test6, ADNI, CAHHM), providing further evidence of the accuracy and consistency of its segmentation output. segcsvdPVS demonstrates robust performance across diverse imaging conditions and improved sensitivity to biologically meaningful associations, supporting its utility as a T1-based PVS segmentation tool.

Для цитирования: Gibson Erin, Ramirez Joel, Woods Lauren Abby, Berberian Stephanie, Ottoy Julie, Scott Christopher J M, Yhap Vanessa, Gao Fuqiang, Coello Roberto Duarte, Valdes Hernandez Maria, Lang Anthony E, Tartaglia Carmela M, Kumar Sanjeev, Binns Malcolm A, Bartha Robert, Symons Sean, Swartz Richard H, Masellis Mario, Singh Navneet, MacIntosh Bradley J, Wardlaw Joanna M, Black Sandra E, ONDRI Investigators, ADNI, CAHHM Investigators, CAIN Investigators, colleagues from the Foundation Leducq Transatlantic Network of Excellence, Lim Andrew S P, Goubran Maged. segcsvdPVS: A Convolutional Neural Network-Based Tool for Quantification of Enlarged Perivascular Spaces (PVS) on T1-Weighted Images.. Human brain mapping. 2026. DOI: 10.1002/hbm.70462.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.