MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0015-0282(16)55935-4

Медицинская библиотека · Fertility and sterility · 1993

Detection of Chlamydia trachomatis in semen of artificial insemination donors by the polymerase chain reaction.

van den Brule A J, Hemrika D J, Walboomers J M, Raaphorst P, van Amstel N, Bleker O P, Meijer C J

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To assess the feasibility of detecting Chlamydia trachomatis in cryopreserved donor semen by a specific, direct polymerase chain reaction (PCR).

DESIGN

Cryopreserved donor semen was tested for the presence of C. trachomatis by a specific PCR, directly applied to semen without prior DNA purification.

SETTING

Tertiary care fertility center in a teaching hospital and university-based laboratory for molecular pathology.

PARTICIPANTS

Cryopreserved semen from 30 donors was investigated. These semen samples had previously given negative results in cell culture for C. trachomatis. Two different ejaculates of each donor, cryopreserved with an interval of 2 years, were retrospectively analyzed.

INTERVENTIONS: None.

MAIN OUTCOME MEASURE: The presence of C. trachomatis as demonstrated by PCR.

RESULTS

In 3 of 30 donors C. trachomatis was detected in both ejaculates, whereas in 2 additional donors only one of the two samples tested positive. Additional samples from 2 positive donors, together with samples from 3 negative donors, were studied more extensively, to test the reproducibility and reliability of PCR results. All ejaculates of the donors, previously positive for C. trachomatis by PCR, indeed appeared to be positive, whereas the samples of the negative donors remained negative.

CONCLUSIONS

The direct PCR is a reliable, sensitive, and valuable method for detection of C. trachomatis in semen. The incidence of contamination of donor semen with C. trachomatis in the donor population in this study stresses the need for rigorous screening of donor semen before artificial insemination, preferably using a sensitive method such as the PCR.

Для цитирования: van den Brule A J, Hemrika D J, Walboomers J M, Raaphorst P, van Amstel N, Bleker O P, Meijer C J. Detection of Chlamydia trachomatis in semen of artificial insemination donors by the polymerase chain reaction.. Fertility and sterility. 1993. DOI: 10.1016/s0015-0282(16)55935-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.