Scientific reports · 2020
Validation of four-dimensional flow cardiovascular magnetic resonance for aortic stenosis assessment.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Archer Gareth T, Elhawaz Alaa, Barker Natasha, Fidock Benjamin, Rothman Alexander, van der Geest R J, Hose Rod, Briffa Norman, Hall Ian R, Grech Ever, Bissell Malenka, Al-Mohammad Abdallah, Treibel Thomas A, Swift Andrew J, Wild James M, Garg Pankaj
Аннотация
The management of patients with aortic stenosis (AS) crucially depends on accurate diagnosis. The main aim of this study were to validate the four-dimensional flow (4D flow) cardiovascular magnetic resonance (CMR) methods for AS assessment. Eighteen patients with clinically severe AS were recruited. All patients had pre-valve intervention 6MWT, echocardiography and CMR with 4D flow. Of these, ten patients had a surgical valve replacement, and eight patients had successful transcatheter aortic valve implantation (TAVI). TAVI patients had invasive pressure gradient assessments. A repeat assessment was performed at 3-4 months to assess the remodelling response. The peak pressure gradient by 4D flow was comparable to an invasive pressure gradient (54 ± 26 mmHG vs 50 ± 34 mmHg, P = 0.67). However, Doppler yielded significantly higher pressure gradient compared to invasive assessment (61 ± 32 mmHG vs 50 ± 34 mmHg, P = 0.0002). 6MWT was associated with 4D flow CMR derived pressure gradient (r = -0.45, P = 0.01) and EOA (r = 0.54, P < 0.01) but only with Doppler EOA (r = 0.45, P = 0.01). Left ventricular mass regression was better associated with 4D flow derived pressure gradient change (r = 0.64, P = 0.04). 4D flow CMR offers an alternative method for non-invasive assessment of AS. In addition, 4D flow derived valve metrics have a superior association to prognostically relevant 6MWT and LV mass regression than echocardiography.
Предметные рубрики MeSH
AgedAged, 80 and overAortic ValveAortic Valve StenosisCardiovascular SystemEchocardiographyEchocardiography, DopplerFemaleFour-Dimensional Computed TomographyHeart Valve Prosthesis ImplantationHumansMagnetic Resonance ImagingMagnetic Resonance Imaging, CineMalePredictive Value of TestsProspective StudiesStroke VolumeTranscatheter Aortic Valve ReplacementTreatment OutcomeVentricular Function, Left