Validation of four-dimensional flow cardiovascular magnetic resonance for aortic stenosis assessment.

Archer Gareth T, Elhawaz Alaa, Barker Natasha, Fidock Benjamin, Rothman Alexander, van der Geest R J, Hose Rod, Briffa Norman, Hall Ian R, Grech Ever, Bissell Malenka, Al-Mohammad Abdallah, Treibel Thomas A, Swift Andrew J, Wild James M, Garg Pankaj

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The management of patients with aortic stenosis (AS) crucially depends on accurate diagnosis. The main aim of this study were to validate the four-dimensional flow (4D flow) cardiovascular magnetic resonance (CMR) methods for AS assessment. Eighteen patients with clinically severe AS were recruited. All patients had pre-valve intervention 6MWT, echocardiography and CMR with 4D flow. Of these, ten patients had a surgical valve replacement, and eight patients had successful transcatheter aortic valve implantation (TAVI). TAVI patients had invasive pressure gradient assessments. A repeat assessment was performed at 3-4 months to assess the remodelling response. The peak pressure gradient by 4D flow was comparable to an invasive pressure gradient (54 ± 26 mmHG vs 50 ± 34 mmHg, P = 0.67). However, Doppler yielded significantly higher pressure gradient compared to invasive assessment (61 ± 32 mmHG vs 50 ± 34 mmHg, P = 0.0002). 6MWT was associated with 4D flow CMR derived pressure gradient (r = -0.45, P = 0.01) and EOA (r = 0.54, P < 0.01) but only with Doppler EOA (r = 0.45, P = 0.01). Left ventricular mass regression was better associated with 4D flow derived pressure gradient change (r = 0.64, P = 0.04). 4D flow CMR offers an alternative method for non-invasive assessment of AS. In addition, 4D flow derived valve metrics have a superior association to prognostically relevant 6MWT and LV mass regression than echocardiography.

Для цитирования: Archer Gareth T, Elhawaz Alaa, Barker Natasha, Fidock Benjamin, Rothman Alexander, van der Geest R J, Hose Rod, Briffa Norman, Hall Ian R, Grech Ever, Bissell Malenka, Al-Mohammad Abdallah, Treibel Thomas A, Swift Andrew J, Wild James M, Garg Pankaj. Validation of four-dimensional flow cardiovascular magnetic resonance for aortic stenosis assessment.. Scientific reports. 2020. DOI: 10.1038/s41598-020-66659-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.