MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/s26030904

Медицинская библиотека · Sensors (Basel, Switzerland) · 2026

Colorimetric Determination of Peroxides: A New Paper-Based Sensor for Detecting Hexamethylene Triperoxide Diamine (HMTD).

Furmanek Wiktoria, Lastivka Viktoriia, Kasprzak Piotr, Mazur Izabela, Baran Piotr Andrzej, Pniewski Wawrzyniec, Kukiełczyński Łukasz, Koszytkowska-Stawińska Mariola, Grabowska-Jadach Ilona, Chudy Michał, Tokarska Katarzyna, Żukowski Kamil, Dybko Artur

СтатьяПеревод в очереди

Аннотация

Homemade explosives (HMEs) are of increasing interest to security forces worldwide due to their widespread utilization by terrorists. Their synthesis is relatively straightforward, requiring only a few readily available chemical compounds. Among the most popular HMEs are organic peroxides, specifically triacetone triperoxide (TATP) and hexamethylene triperoxide diamine (HMTD). This manuscript reports on a paper-based sensor developed for the detection of HMTD. The sensor facilitates fast, inexpensive, and simple detection of this peroxide. The developed sensor was compared with well-established commercial and in-house-developed iodometric tests typically used for peroxide determination. The colorimetric principle was based on the use of a potassium iodide and citric acid solution applied to a paper substrate. The HMTD and TATP samples were prepared in an acetone-water mixture (1:1, v/v). The sensor was able to detect HMTD down to a limit of 0.01 mg/mL. The developed sensor does not exhibit cross-reactivity with other explosives, including TATP. Furthermore, an HSV analysis of the photographs was performed using the Trigit application.

Для цитирования: Furmanek Wiktoria, Lastivka Viktoriia, Kasprzak Piotr, Mazur Izabela, Baran Piotr Andrzej, Pniewski Wawrzyniec, Kukiełczyński Łukasz, Koszytkowska-Stawińska Mariola, Grabowska-Jadach Ilona, Chudy Michał, Tokarska Katarzyna, Żukowski Kamil, Dybko Artur. Colorimetric Determination of Peroxides: A New Paper-Based Sensor for Detecting Hexamethylene Triperoxide Diamine (HMTD).. Sensors (Basel, Switzerland). 2026. DOI: 10.3390/s26030904.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.