Fiber-Tip Polymer Microcantilever for Fast and Highly Sensitive Hydrogen Measurement.

Xiong Cong, Zhou Jiangtao, Liao Changrui, Zhu Meng, Wang Ying, Liu Shen, Li Chi, Zhang Yunfang, Zhao Yuanyuan, Gan Zongsong, Venturelli Leonardo, Kasas Sandor, Zhang Xuming, Dietler Giovanni, Wang Yiping

СтатьяПеревод в очереди

Аннотация

Hydrogen as an antioxidant gas has been widely used in the medical and biological fields for preventing cancer or treating inflammation. However, controlling the hydrogen concentration is crucial for practical use due to its explosive property when its volume concentration in air reaches the explosive limit (4%). In this work, a polymer-based microcantilever (μ-cantilever) hydrogen sensor located at the end of a fiber tip is proposed to detect the hydrogen concentration in medical and biological applications. The proposed sensor was developed using femtosecond laser-induced two-photon polymerization (TPP) to print the polymer μ-cantilever and magnetron sputtering to coat a palladium (Pd) film on the upper surface of the μ-cantilever. Such a device exhibits a high sensitivity, roughly -2 nm %-1 when the hydrogen concentration rises from 0% to 4.5% (v/v) and a short response time, around 13.5 s at 4% (v/v), making it suitable for medical and environmental applications. In addition to providing an ultracompact optical solution for fast and highly sensitive hydrogen measurement, the polymer μ-cantilever fiber sensor can be used for diverse medical and biological sensing applications by replacing Pd with other functional materials.

Для цитирования: Xiong Cong, Zhou Jiangtao, Liao Changrui, Zhu Meng, Wang Ying, Liu Shen, Li Chi, Zhang Yunfang, Zhao Yuanyuan, Gan Zongsong, Venturelli Leonardo, Kasas Sandor, Zhang Xuming, Dietler Giovanni, Wang Yiping. Fiber-Tip Polymer Microcantilever for Fast and Highly Sensitive Hydrogen Measurement.. ACS applied materials & interfaces. 2020. DOI: 10.1021/acsami.0c06179.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.