DOI 10.1002/jms.3732

Медицинская библиотека · Journal of mass spectrometry : JMS · 2016

Low-pressure barrier discharge ion source using air as a carrier gas and its application to the analysis of drugs and explosives.

Usmanov Dilshadbek T, Yu Zhan, Chen Lee Chuin, Hiraoka Kenzo, Yamabe Shinichi

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

In this work, a low-pressure air dielectric-barrier discharge (DBD) ion source using a capillary with the inner diameter of 0.115 and 12 mm long applicable to miniaturized mass spectrometers was developed. The analytes, trinitrotoluene (TNT), 1,3,5-trinitroperhydro-1,3,5-triazine (RDX), 1,3,5,7-tetranitroperhydro-1,3,5,7-tetrazocine (HMX), pentaerythritol tetranitrate (PETN), nitroglycerine (NG), hexamethylene triperoxide diamine (HMTD), caffeine, cocaine and morphine, introduced through the capillary, were ionized by a low-pressure air DBD. The ion source pressures were changed by using various sizes of the ion sampling orifice. The signal intensities of those analytes showed marked pressure dependence. TNT was detected with higher sensitivity at lower pressure but vice versa for other analytes. For all analytes, a marked signal enhancement was observed when a grounded cylindrical mesh electrode was installed in the DBD ion source. Among nine analytes, RDX, HMX, NG and PETN could be detected as cluster ions [analyte + NO3 ](-) even at low pressure and high temperature up to 180 °C. The detection indicates that these cluster ions are stable enough to survive under present experimental conditions. The unexpectedly high stabilities of these cluster ions were verified by density functional theory calculation.

Для цитирования: Usmanov Dilshadbek T, Yu Zhan, Chen Lee Chuin, Hiraoka Kenzo, Yamabe Shinichi. Low-pressure barrier discharge ion source using air as a carrier gas and its application to the analysis of drugs and explosives.. Journal of mass spectrometry : JMS. 2016. DOI: 10.1002/jms.3732.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.