Diagnostic ability of Cirrus anterior segment optical coherence tomography to differentiate between binary grades of narrow angles seen on gonioscopy.

Chelerkar Vidya, Solanki Vidhi, Kalyani Vks, Patil Nikita

СтатьяПеревод в очереди

Аннотация

PURPOSE: To assess diagnostic performance of Cirrus Anterior Segment Optical Coherence Tomography (ASOCT) parameters to differentiate gonioscopic grades of narrow angles.

METHODS

This prospective cross sectional study included 100 eyes with clinically diagnosed angle closure disease. Quantitative ASOCT parameters such as angle width, angle opening distance (AOD), trabecular iris space area (TISA) at scleral spur distances of 500 and 750µm were measured.Shaffer's grading system was used to grade narrow angles. Area under the receiver operating characteristic curves (AUCs) were generated to assess diagnostic performance of these measurements to differentiate grades of narrow angles.

RESULTS

68 eyes were available for analysis. . Correlation between grade 0/1 on gonioscopy with 0-10° on ASOCT was seen in 81.3% of eyes in the nasal angle and 76.1% of eyes in the temporal angle ( P < 0.001), and grade 2 angle with 11-20° on ASOCT was seen in 80.0% of eyes in the nasal angle and 72.7% eyes in temporal angle ( P < 0.001). AUC for grade 0/1 and grade 2 angles on gonioscopy was highest for AOD500 nasally (0.80 [95% confidence interval (CI), 0.68-0.88]) while temporally, it was highest for TISA500 (0.72 [95% CI, 0.60-0.82]). Kappa coefficient between gonioscopy vs ASOCT was found to be 0.57 (95% CI, 0.36-0.75) nasally and 0.46 (95% CI, 0.24-0.67) temporally.

CONCLUSION

Discrimination capability of ASOCT parameters appears to be limited for differentiating between various grades of narrow angle. Further studies with larger sample sizes are required to study the utility of ASOCT in this aspect.

Для цитирования: Chelerkar Vidya, Solanki Vidhi, Kalyani Vks, Patil Nikita. Diagnostic ability of Cirrus anterior segment optical coherence tomography to differentiate between binary grades of narrow angles seen on gonioscopy.. Indian journal of ophthalmology. 2026. DOI: 10.4103/ijo.ijo_3331_25.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.