Online circular contrast perimetry performed in glaucoma patients in Sub-Saharan Africa: a multi-centre comparative study in Nigeria.

Olawoye Olusola, Meyerov Joshua, Bigirimana Deus, Sarimiye Tarela Frederick, Okudo Adaora Chinwendu, Kalambe Aisha Sheriff, Adenrele Kuburat Oluwatoyin, Ogbonnaya Chimdia, Ibanga Affiong, Adekoya Bola, Ejiofor Mary, Ezenwa Adanma, Awoyesuku Elizabeth Akon, Uche Nkechiyere, Hussain Oluwatobi James, Vivian Anene Ezinne, Garba Farouk, Lawal Funmilayo, Skalicky Simon

СтатьяПеревод в очереди

Аннотация

BACKGROUND/

OBJECTIVES

Online circular contrast perimetry (OCCP) provides visual field testing on any computer or tablet, without additional hardware. Its performance has not been evaluated in an African cohort. This study compared the performance of OCCP to standard automated perimetry (SAP) in a cohort of Nigerian patients with glaucoma.

SUBJECTS/

METHODS

Across 404 patients (198 males, 206 females), OCCP mean deviation (MD) and pattern standard deviation (PSD) were compared with SAP using paired analyses, Bland-Altman plots, intraclass correlation coefficients (ICC) and Pearson correlation. The correlation between MD and vertical cup-to-disc ratio (VCDR) was assessed using linear regression. Reliability indices, including fixation losses (FL), false positives (FP), and false negatives (FN), were also compared.

RESULTS

Mean OCCP MD was higher than SAP in both eyes (p < 0.001). Bland-Altman analysis demonstrated a positive bias toward higher MD values with OCCP (1.09-1.53 dB), while ICCs indicated moderate reliability and correlation with SAP (0.52-0.53). MD showed stronger correlations with VCDR for OCCP than for SAP (r = -0.41 to -0.48 vs -0.32 to -0.41), although these differences were not statistically significant. Mean PSD values were similar between devices with minimal bias (-0.10 to -0.16 dB); however, agreement and correlation were poor (ICC 0.39; r = 0.39-0.40). Reliability indices (FL, FP, FN) were comparable between OCCP and SAP.

CONCLUSIONS

OCCP demonstrates consistent moderate agreement with SAP for MD, with similar reliability. As a potential screening and surveillance tool, OCCP could be used to substantiate visual field testing in SSA, especially where perimetry availability is limited.

Для цитирования: Olawoye Olusola, Meyerov Joshua, Bigirimana Deus, Sarimiye Tarela Frederick, Okudo Adaora Chinwendu, Kalambe Aisha Sheriff, Adenrele Kuburat Oluwatoyin, Ogbonnaya Chimdia, Ibanga Affiong, Adekoya Bola, Ejiofor Mary, Ezenwa Adanma, Awoyesuku Elizabeth Akon, Uche Nkechiyere, Hussain Oluwatobi James, Vivian Anene Ezinne, Garba Farouk, Lawal Funmilayo, Skalicky Simon. Online circular contrast perimetry performed in glaucoma patients in Sub-Saharan Africa: a multi-centre comparative study in Nigeria.. Eye (London, England). 2026. DOI: 10.1038/s41433-026-04810-9.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.