Evaluating the Acceptability and Pilot Diagnostic Accuracy of a Visually Independent Test Battery of Neurocognition (VISION-Cog).

Yee Hiromi, Ho Aricia Xin Yi, Wong Chiew Meng Johnny, Tan Wei Lin, Fenwick Eva K, Gupta Preeti, Ng Adeline S L, Vu Tai Anh, Doshi Kinjal, Lamoureux Ecosse L, Man Ryan E K

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Cognitive impairment (CI) may be overdiagnosed in individuals with vision impairment (VI) due to the vision-dependent design of current cognitive assessment tools. This cross-sectional study evaluated the acceptability and diagnostic accuracy (pilot) of the Visually Independent Test Battery of Neurocognition (VISION-Cog) protocol, against gold-standard neurologist diagnosis.

METHODS

Community-dwelling older adults with near binocular presenting VI (near visual acuity [NVA] ≥ 0.2 logarithm of the minimum angle of resolution [LogMAR] units) were recruited from the Population Health and Eye Disease Profile in Elderly Singaporeans (PIONEER) study. Participants underwent VISION-Cog and the Singapore-validated Montreal Cognitive Assessment (MoCA-SG) testing and were referred for neurologist evaluation based on standardized referral protocols. The acceptability of the VISION-Cog was assessed through study completion rates, test duration, and the qualitative feedback. Vision-Cog's diagnostic accuracy (pilot) against neurologist evaluation was analyzed using binary logistic regression and C-statistics to estimate area under the receiver operating curve (AUC) with corresponding sensitivity and specificity.

RESULTS

Out of forty-five participants (mean age [SD]: 73.8 [6.1 years]; mean NVA [SD]: 0.47 [0.14] LogMAR; and 54.1% female), 37 (82.2%) completed the protocol. The mean VISION-Cog completion time [SD] was 59 m 57 s (7 m 18 s). Qualitatively, participants found the testing time acceptable. The VISION-Cog achieved an AUC of 0.930 against neurologist diagnosis, with 100.0% sensitivity and 78.0% specificity.

CONCLUSIONS

The VISION-Cog demonstrated satisfactory preliminary diagnostic accuracy and good acceptability indices in older Asian adults, supporting the need of larger studies to confirm its diagnostic accuracy of CI and clinical utility in those with VI.

Для цитирования: Yee Hiromi, Ho Aricia Xin Yi, Wong Chiew Meng Johnny, Tan Wei Lin, Fenwick Eva K, Gupta Preeti, Ng Adeline S L, Vu Tai Anh, Doshi Kinjal, Lamoureux Ecosse L, Man Ryan E K. Evaluating the Acceptability and Pilot Diagnostic Accuracy of a Visually Independent Test Battery of Neurocognition (VISION-Cog).. Medical sciences (Basel, Switzerland). 2026. DOI: 10.3390/medsci14030344.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.