PURPOSE: To determine the value of the 10-2 test of the Humphrey Field Analyzer (Carl Zeiss Meditec) in detecting visual field (VF) progression in early glaucoma.

DESIGN

Prospective longitudinal study.

PARTICIPANTS

Patients with open-angle glaucoma and healthy participants.

METHODS

Participants were examined with the 24-2 and 10-2 tests every 4 months. Only those with 5 pairs of tests or more were included. To analyze the same area as the 10-2, only the central 12 test locations of the 24-2 test were included, from which global and quadrant mean deviation (MD) slopes and pointwise total deviation (TD) slopes were computed. A range of criteria for progression based on pointwise TD slope cutoffs was used.

MAIN OUTCOME MEASURES: Measures included the area under the receiver operating characteristic curve (AUC) separating patients with glaucoma from healthy participants for global, sectoral, and pointwise analyses and overlap in the proportion of patients identified by the 2 tests at matched specificity.

RESULTS

One eye each from 96 patients with glaucoma with early visual field damage and 56 healthy participants was included in the analysis. The participants were followed up for a median of 4.69 and 4.49 years with 13 and 11 pairs of tests, respectively. The AUCs of the MD slopes for the 2 tests were not significantly different for global (P = 0.25) or quadrant (P > 0.11) analysis. At 90% specificity for global MD slope, the overlap in patients classified as progressing with both tests was 53%, whereas for quadrant MD slope, the overlap was less. The AUCs were not different for pointwise slope cutoffs of more than -1.25 dB/year, but were significantly higher for the 10-2 test when cutoffs were -1.25 dB/year or less. Patients showing progression with only the 10-2 test with steeper pointwise slope cutoffs showed worse baseline MD on the 10-2, but not 24-2, test.

CONCLUSIONS

For global and sectoral analyses, little evidence showed that the 10-2 test provided additional information about central visual VF compared with the 24-2 test. Pointwise analyses support the use of the 10-2 test for following up patients with selectively worse central VF loss at baseline and who are at risk of faster progression.

FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

Для цитирования: Tomita Ryo, Salh Dominique, Dyachok Oksana M, West Michael E, Sharpe Glen P, Rafuse Paul E, Shuba Lesya M, Nicolela Marcelo T, Chauhan Balwantray C. Value of 10-2 Visual Field Testing for Detecting Progression in Patients with Glaucoma.. Ophthalmology. 2026. DOI: 10.1016/j.ophtha.2026.06.029.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.