MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/jcm15124791

Медицинская библиотека · Journal of clinical medicine · 2026

Real-World Application of Microscope-Integrated 400 kHz Swept-Source Intraoperative OCT in Ophthalmic Surgery.

Zhang Xifang, Liu Shuang, Guo Jing, Yang Shuai, Yao Tengteng, Zhang Yuheng, Wang Zhaoyang

СтатьяПеревод в очереди

Аннотация

Objectives

We aimed to descriptively evaluate the feasibility and clinical utility of TowardPi BO (4K ultra-HD microscope integrated with a 400 kHz swept-source intraoperative optical coherence tomography (SS-iOCT) system) in managing various ophthalmic surgical conditions in a real-world setting.

Methods

We analyzed surgical videos and data from 123 consecutive cases that underwent elective surgery with the assistance of this SS-iOCT system at Beijing Tongren Hospital between 2 September 2025 and 10 February 2026. Cases were included when the iOCT provided critical, real-time information that directly influenced surgical decision-making or technique modification. Cases were excluded if iOCT served only routine confirmatory or educational purposes without altering the surgical plan.

Results

A total of 72 surgical cases were included, comprising 7 intraocular lens implantations with ciliary sulcus fixation, 19 macular holes, 3 cases of macular hole retinal detachment (MHRD), 4 cases of macular schisis with or without foveal detachment (MSRD), 12 cases of submacular hemorrhage, 20 cases of rhegmatogenous retinal detachment (RRD), and 7 intraocular mass lesions. The 400 kHz SS-iOCT significantly aided in surgical visualization, guided real-time decision-making, and prompted modifications in surgical techniques.

Conclusions

To our knowledge, this is the first real-world study to evaluate the application of a 400 kHz SS-iOCT system across a wide spectrum of ophthalmic conditions, including its novel use in intraocular tumors. From routine to complex surgical cases, SS-iOCT enhances surgical precision and facilitates real-time decision-making, ultimately contributing to improved surgical outcomes.

Для цитирования: Zhang Xifang, Liu Shuang, Guo Jing, Yang Shuai, Yao Tengteng, Zhang Yuheng, Wang Zhaoyang. Real-World Application of Microscope-Integrated 400 kHz Swept-Source Intraoperative OCT in Ophthalmic Surgery.. Journal of clinical medicine. 2026. DOI: 10.3390/jcm15124791.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.