DOI 10.3390/bioengineering13060685
Clinical and Wavefront Outcomes After Femtosecond Laser Versus Mechanical Microkeratome Lasik: A Prospective Paired-Eye Comparative Study.
Аннотация
Background/
Objectives
The technique used for flap creation in laser in situ keratomileusis (LASIK) may influence postoperative optical quality and visual outcomes. This prospective randomized paired-eye study compared higher-order aberrations (HOAs) and visual acuity outcomes following femtosecond laser-assisted versus mechanical microkeratome-assisted LASIK. Materials and
Methods
Forty-four patients (88 eyes) underwent bilateral LASIK. In each patient, one eye was randomly assigned to high-frequency femtosecond laser flap creation (Femto LDV), and the fellow eye to mechanical microkeratome flap creation (Amadeus II). Inclusion criteria were stable refraction, central corneal thickness ≥ 520 µm, and normal corneal topography. HOAs were measured using Hartmann-Shack wavefront aberrometry over a 6 mm pupil diameter. Uncorrected and corrected distance visual acuity (UDVA and CDVA) were evaluated preoperatively and postoperatively at 1 day, 1 week, and 1, 3, and 6 months.
Results
Both techniques induced significant postoperative changes in specific Zernike coefficients and an increase in total HOA root mean square (RMS) values (p < 0.05). A reduction in spherical aberration (Z4,0) was observed in both groups, while technique-specific changes were noted in individual aberration components including an increase in horizontal trefoil (Z3,3) in the femtosecond and a decrease in horizontal coma (Z5,1) in the microkeratome group. However, paired-eye comparisons revealed no statistically significant differences in total HOA six months postoperative. Despite comparable aberrometric outcomes, femtosecond-treated eyes demonstrated significantly better UDVA and CDVA at all postoperative time points (p < 0.05).
Conclusions
Femtosecond laser-assisted and microkeratome-assisted LASIK resulted in comparable changes in higher-order aberrations, despite differing pattern in individual aberration components. The observed differences in visual acuity outcomes were not reflected in wavefront metrics, suggesting that postoperative visual performance may be influenced by factors.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.