MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/adma.73813

Медицинская библиотека · Advanced materials (Deerfield Beach, Fla.) · 2026

Nocturnal Intraocular Pressure Monitoring With a Soft Contact Lens Sensor for Glaucoma Management.

Dai Yumin, Long Tristan Michael, Oladele Oluwabunmi T, Lee Youngoh, Li Feiyang, Wang Ziheng, Oh Yeonji, Lee Junsang, Park Taewoong, Yu Tianhao, Hong Seokkyoon, Lim Kyeonghee, Jeong Jinheon, Schneider Dawn Meyer, Ra Hyerim, Boudouris Bryan W, Shaw Gillian C, Park Shin Ae, Kollbaum Pete S, Lee Chi Hwan

СтатьяПеревод в очереди

Аннотация

Measurement of nocturnal intraocular pressure (IOP) is essential for glaucoma management, yet recumbent IOP fluctuations during sleep remain largely unmeasured outside the clinic. Although existing eye-worn wearable sensors enable noninvasive IOP monitoring, limitations in sensitivity, closed-eye performance, and overnight wearability restrict accurate assessment of nocturnal IOP changes under sleep conditions. Here, we present a soft contact lens sensor designed for continuous monitoring of nocturnal IOP in a home setting. The sensor integrates a compliant conductor-based inductive-capacitive circuit directly onto a commercial soft contact lens, enabling close conformity to the eye. This design achieves the highest IOP sensitivity reported to date among wearable soft contact lens sensors, representing a substantial improvement over our earlier designs. As a result, the sensor provides stable and accurate IOP measurements under recumbent, closed-eye sleep conditions. Animal studies in rabbits and dogs and pilot human measurements in healthy and glaucomatous eyes support preliminary ocular tolerability and feasible sensor performance, enabling posture-dependent IOP tracking and detection of sleep-relevant pressure elevations under the tested conditions. These results address key limitations of earlier contact lens sensors and support at-home monitoring of nocturnal IOP dynamics.

Для цитирования: Dai Yumin, Long Tristan Michael, Oladele Oluwabunmi T, Lee Youngoh, Li Feiyang, Wang Ziheng, Oh Yeonji, Lee Junsang, Park Taewoong, Yu Tianhao, Hong Seokkyoon, Lim Kyeonghee, Jeong Jinheon, Schneider Dawn Meyer, Ra Hyerim, Boudouris Bryan W, Shaw Gillian C, Park Shin Ae, Kollbaum Pete S, Lee Chi Hwan. Nocturnal Intraocular Pressure Monitoring With a Soft Contact Lens Sensor for Glaucoma Management.. Advanced materials (Deerfield Beach, Fla.). 2026. DOI: 10.1002/adma.73813.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.