MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejmp.2026.105833

Медицинская библиотека · Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026

Occupational radiation doses in CT-guided interventions: A multicentre evaluation with special emphasis on lung biopsies and eye lens doses.

Hartikainen Hemmo, Pekkarinen Antti, Kaasalainen Touko, Kortesniemi Mika

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

PURPOSE: This study aimed to investigate eye lens and whole-body radiation doses received by interventional radiologists during CT-guided procedures, with a particular focus on lung biopsies.

METHODS

Simultaneous measurements of eye lens dose equivalent Hp(3), deep-dose equivalent Hp(10), and shallow-dose equivalent Hp(0.07) were conducted under clinical conditions during CT-guided procedures in five Finnish hospitals during four separate four-week measurement periods. Hp(3) was measured using EYE-D thermoluminescent dosimeters, while Hp(10) and Hp(0.07) were recorded using DIS-1 dosimeters. The Hp(3)/Hp(10) and Hp(3)/Hp(0.07) ratios, and Hp(3) to dose-length product (DLP) were analysed to assess whether routinely measured quantities can provide a rough indication of eye lens dose in CT-guided procedures. The doses per CT procedure were analysed for all aforementioned dose equivalents to evaluate the annual exposures. Dosimeter calibration and quality control were performed at a secondary standard dosimetry laboratory. Staff positioning, radiation protection practices, and procedural variables were explored in relation to differences in observed exposure levels across hospitals and procedures.

RESULTS AND

CONCLUSIONS

Occupational radiation exposure during CT-guided procedures were generally negligible when appropriate radiological practices and protective equipment were used. One hospital showed significantly higher dose values due to the primary use of fluoroscopy and absence of a lead glass screen. Despite this aberrant result, exposure levels remained below annual occupational dose limits in all hospitals. Routinely measured Hp(10) and Hp(0.07) showed a strong relationship with Hp(3) in the measurable dose data, suggesting that they may provide a rough indication of the order of magnitude of eye lens dose.

Для цитирования: Hartikainen Hemmo, Pekkarinen Antti, Kaasalainen Touko, Kortesniemi Mika. Occupational radiation doses in CT-guided interventions: A multicentre evaluation with special emphasis on lung biopsies and eye lens doses.. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). 2026. DOI: 10.1016/j.ejmp.2026.105833.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.