MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.biomaterials.2025.123520

Медицинская библиотека · Biomaterials · 2025

Triple-molded, reinforced arrowhead microneedle patch of dual human-derived matrix for integrated management of diabetic wounds.

Zhuang Ze-Ming, Wang Yong, Chen Li, Wu Zhang-Rui, Zhang Tao, Bei Ho-Pan, Feng Zi-Xuan, Wang Yi, Guo Kai, Hsu Yi-Ying, Chen Jun, Du Yong-Zhong, Chen Jingdi, Zhao Xin, Zhu Ning-Wen, Tan Wei-Qiang

СтатьяПеревод в очереди

Аннотация

Platelet-rich plasma (PRP) is often administered with gauze for wound management clinically. However, this treatment method suffers from poor contact, drug wastage and limited delivery depth compromising therapeutic efficacy. Local injections address some of these challenges but are invasive and cause significant pain. In response, we develop a transdermal delivery system utilizing type 1 recombinant human collagen (1-RHC) to integrate PRP within a hydrogel microneedle patch (MNP). The reaction of methacrylic anhydride with 1-RHC yields methacrylate RHC (1-RHCMA), which when combined with PRP, self-assembles into an arrow-shaped MNP, 1-RHCMA-PRP Arrow-MNP (RPAM) via a triple-molding process. The 1-RHCMA-PRP hydrogel demonstrates pro-epithelial, pro-angiogenesis, anti-inflammatory, and antibacterial properties in vitro. When applied to rat diabetic wound models, RPAM also regulates collagen alignment and demonstrates robust mechanical properties which can prevent pathological scar formation by stabilizing the wound bed. Transcriptome sequencing further confirms that RPAM promotes excellent healing via pro-keratinization and modulation of immune response. Additionally, RPAM exhibits no toxicity to any organs within the organism, mitigating any immunogenic concerns. Herein, our RPAM dual-derived from PRP and 1-RHCMA can manage wound complications with minimal invasiveness and excellent wound closure, offering significant potential for clinical translation.

Для цитирования: Zhuang Ze-Ming, Wang Yong, Chen Li, Wu Zhang-Rui, Zhang Tao, Bei Ho-Pan, Feng Zi-Xuan, Wang Yi, Guo Kai, Hsu Yi-Ying, Chen Jun, Du Yong-Zhong, Chen Jingdi, Zhao Xin, Zhu Ning-Wen, Tan Wei-Qiang. Triple-molded, reinforced arrowhead microneedle patch of dual human-derived matrix for integrated management of diabetic wounds.. Biomaterials. 2025. DOI: 10.1016/j.biomaterials.2025.123520.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.